Installation Instructions
48
46900V001_Rev-D_EN
11. Connections and special functions of the ceiling
control unit
11.1 Ceiling control unit circuit board
WL
24V/1A
Signal
COM
GND
+24V
~ 24 V AC
Light
gn
rt
+
-
SOMMER
Antriebs- u.
FunktechnikGmb
ACCU
GT-G-1
PCxxxxxxx
L`
N`
N
L
KEYPAD
1
4
S1
ON
1234
1
2
3
4
11
9
5
6
7
8
10
Fig. Ceiling control unit circuit board (complete version*)
Connection options to the ceiling control unit
1
DIP switches 7 2-pin terminal block
24 V/AC transformer secondary side
2 ACCU slot
Terminal for accumulator
8 Circuit board label
3 Slot, KEYPAD, black
Conex connection
9 2-pin terminal block
Chain and track, 24 V DC
4 Slot
Terminal for relay
10 Light slot, white
Connection for Lumi
+
supplemental lighting
5 2-pin terminal block
Supply voltage
220 - 240 V AC, 50/60 Hz
11 8-pin terminal block
• Button, potential-free
• Warning light (24 V DC, max. 25 W)
• 2/4-wire photocell
(max. 100 mA regulated)
6 2-pin terminal block
Transformer primary side
220 - 240 V AC, 50/60 Hz
*The version can vary depending on the type. This means the use of accessories can vary.
A connection diagram can be found in Chapter “19. Connection diagrams and functions of the DIP switches”.