Installation Instructions
35
46900V001_Rev-D_EN
9. Commissioning
9.2 Initial operation
Before initial operation, read this chapter with special
care to ensure that you can make the adjustments to the
operator safely and optimally.
WARNING
Danger of entrapment!
If the force setting is too high, persons
or animals in the movement area of the
door may be trapped and pulled along
with the door. Severe injuries or death
may result.
► The force setting is relevant to safety
and must be carried out by a trained
specialist.
► You must proceed with extreme caution
if you check and if necessary adjust the
force setting.
► Please note that the operator may only
be operated if a non-hazardous force
value has been set.
► Select the force setting low enough to
eliminate any danger of injury by the
closing force.
NOTE
Do not use a metal object to set the
DIP switches, because this may damage
the DIP switches or the circuit board.
Use a suitable tool to set the DIP switches,
such as a at, thin plastic object.
INFORMATION
The force setting must be checked after
installation of the operator. See also
chapter "13.1 Testing obstacle detection."
The operator may only be used:
• in combination with door types in the reference list
which can be found at:
http://som4.me/cgdo
For compliance with EN 13241-1, before initial operation,
the door type must be selected and set on the motor
carriage with the DIP switch.
The factory setting of the DIP switches on the motor
carriage is "OFF", which is then applicable for sectional
doors.
DIP switch on
motor carriage
ON
OFF
1
ON
1
2
3
4
• Automatic
closing function
activated
• Automatic
closing
function
deactivated
2
ON
1
2
3
4
• Partial opening
activated/
• Lighting
function
deactivated
• Partial
opening
deactivated/
• Lighting
function
activated
3+4
ON
1
2
3
4
3
ON
1
2
3
4
4
ON
1
2
3
4
The motor carriage has an automatic force setting. The
motor carriage memorizes the required force during the
OPEN and CLOSE door movements and stores it when
the end position has been reached.
INFORMATION
During initial operation:
• Stay in the garage, particularly when
programming.
• Obstacle detection has not yet been
coordinated with the door, and the
operator is in the programming phase.
INFORMATION
The operating forces can be modied and
adjusted with SOMlink and a WiFi-enabled
device.