Installation Instructions

28
46900V001_Rev-D_EN
100 mm
700 mm
10 mm
65 mm
13 mm
Fig. 9 Fig. 10
9. Align the track parallel to centre of the door at
the rear.
Align the ceiling bracket.
The distance between the ceiling control unit and the
ceiling holder should be 100 - 700 mm. The ceiling
bracket should be installed in this area.
Check the alignment of the track with a spirit level if
necessary.
10. Mark the holes on the ceiling for the ceiling holder.
Drill two holes (Ø 10 x 65 mm deep).
Insert the wall plugs.
Insert two screws with washers and screw the
perforated strip to the ceiling.
Tighten the screws.
The track is attached to the ceiling.
Fig. 11
CAUTION
Risk of injury to hands!
Rough, projecting metal parts may
cause abrasions and cuts when picked
up or touched.
The projecting perforated strips must be
sawn off and deburred to prevent injury.
Wear safety gloves when deburring.
11. The projecting perforated strips must be shortened.
< 1,8 m
2x
Fig. 12
WARNING
Danger of entrapment!
Persons or animals in the movement
area of the door may be trapped in a
loop of the emergency release cord and
the door may be accidentally unlocked.
Severe injuries or death may result.
The emergency release handle which is
included must be used.
NOTE
The emergency release handle may cause
damage, e.g. scratches on the vehicle.
The distance between the garage oor and
the emergency release cord must be less
than 1.8 m.
The emergency release handle must be at
least 50 mm from moving and xed parts
throughout its complete path.
12. Attach the emergency release handle:
Pull the cord through the emergency release handle.
Tie a double knot in the cord at an appropriate point.
Pull the emergency release handle over the double
knot. If necessary, shorten the cord or lengthen it
with suitable materials.
6. Installation