Installation Instructions

23
46900V001_Rev-D_EN
6. Installation
6.2 Preparation for installation
Before installation, you must check whether the
operator is suitable for the door, see also Chapter
"3.7 Technical data".
The operator may only be used:
in combination with door types in the reference list
which can be found at:
http://som4.me/cgdo
Removal of actuation parts
WARNING
Danger of entrapment!
Persons or animals may be trapped
by straps or cords and pulled into the
movement zone of the door. Severe
injuries or death may result.
Remove straps and cords used for
mechanical actuation of the door.
Before installation remove:
manual locking on door
all cords or straps necessary to operate the door
by hand.
Disabling mechanical locks
NOTE
If locks or other locking systems are
installed on a mechanical door, they may
block the operator. This may cause faults
or damage to the operator.
Before the installation of the operator,
all mechanical locking systems must be
disabled.
The mechanical lock on a door with an operator must
be removed or disabled if it is not compatible with the
operator.
Checking the mechanism and weight balance
WARNING
Danger due to falling parts of
doors or complete door panels!
Wires, spring sets and other ttings can
be damaged and break. The door panel
may fall. Persons or animals may be
struck by falling parts of the door or the
complete door panel. Severe injuries or
death may result.
Before installation, qualified personnel must
check the following and adapt if necessary:
wires,springsetsandotherttingsof
the door.
the weight balance of the door.
WARNING
Danger of entrapment!
If the force setting is too high, persons
or animals in the movement area of the
door may be trapped and pulled along
with the door. Severe injuries or death
may result.
The force setting is relevant to safety
and must be carried out by a trained
specialist.
You must proceed with extreme caution
if you check and if necessary adjust the
force setting.
NOTE
If the weight compensation of the door is
incorrectly adjusted, the operator may be
damaged.
The door must be stable.
It must not bend, rotate or twist when
opening and closing.
The door must move easily in its tracks.
1. Check the mechanisms of the door, such as wire
cables, spring sets and other fittings.