Installation Instructions
9
46900V001_Rev-D_EN
• in good technical condition
• with attention to safety and hazards by trained users.
1.9 Improper use of the operator
Any other use or additional use that has not been
described in Chapter 1.8 constitutes improper use.
The user bears the sole responsibility for any risk
involved.
The manufacturer's warranty will be voided by:
• damage caused by other use and improper use
• use with defective parts
• unauthorisedmodicationstotheoperator
• modicationsandnon-approvedprogrammingofthe
operator and its components
The door must not be part of a fire protection system, an
evacuation path or an emergency exit that automatically
closes the door in the event of fire. Installation of the
operator will prevent automatic closing.
Observe the local building regulations.
The operator may not be used in:
• areas with explosion hazard
• very salty air
• aggressive atmosphere, including chlorine
1.10 Qualifications of personnel
People under the influence of drugs, alcohol, or
medications that can influence their ability to react may
not work on the operator.
After installation of the operator, the person responsible
for the installation of the operator must complete an
EC Declaration of Conformity for the door system in
accordance with Machinery Directive 2006/42/EC and
apply the CE mark and a type plate to the door system.
This also applies if the operator is retrofitted to a
manually operated door. In addition, a handover protocol
and an inspection book must be completed.
The following is available:
• EC Declaration of Conformity
• handover protocol for the operator
http://som4.me/konform
Trained qualied specialist for installation,
commissioning and disassembly
This installation and operating manual must be read,
understood and complied with by a qualified specialist
who installs or performs maintenance on the operator.
Work on the electrical system and live parts may be
performed only by a trained electrician in accordance
with EN 50110-1.
The installation, commissioning and disassembly of the
operator may only be performed by a qualified specialist.
The qualified specialist must be familiar with the following
standards:
• EN 13241-1 Doors and gates
- Product standard
• EN 12604 Doors and gates - Mechanical aspects
- Requirements
• EN 12605 Doors and gates - Mechanical aspects
- Test methods
• EN 12445 and EN 12453 -
Safety in use of power-operated doors
A qualified specialist is a person ordered by the installer.
The qualified specialist must instruct the user:
• on the operation of the operator and its dangers
• on the handling of the manual emergency release
• on regular maintenance, testing and care which the
user can carry out
The user must be informed that other users must be
instructed on the operation of the operator, its dangers as
well as the emergency release.
The user must be informed about which work must only
be performed by a qualified specialist:
• installation of accessories
• settings
• regular maintenance, testing and care
• troubleshooting and repairs
The following documents for the door system must be
handed over to the user:
• EC Declaration of Conformity
• handover protocol and inspection book
• the installation and operating manuals for the
operator and the door
1. About this installation and operating manual