Installation Instructions

79
46900V001_Rev-D_EN
19. Connection diagrams and functions of the
DIP switches
DIP switches
on the motor
carriage ON
OFF
ON
1
2
3
4
Automatic
closing
function
activated
Automatic
closing
function
deactivated
ON
1
2
3
4
Partial
opening
activated/
lighting
function
deactivated
Partial
opening
deactivated/
lighting
function
activated
ON
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
DIP switches
on the ceiling
control unit ON
OFF
ON
1
23
4
"Conex" additional
circuit board
T1denesdoor
OPEN
T2denesdoor
CLOSE
"Conex" additional
circuit board
T1 pulse sequence
T2 lighting function/
partial opening
ON
1234
Door status display
relay is activated
during door
movement and if the
door is not closed*
Lighting function
ON
1234
Continuous power to
the complete system
activated
Power-saving mode
activated
ON
1234
COM and Signal
activated as button
input (partial
opening)
COM and Signal
activated as safety
contact for photocell
* e.g.: door status display
*500 mA are only available if an LED warning light (max. 3 W) or no warning light is connected
Warning light
Signal
GND
24 V AC 220–240 V AC 220–240 V AC
Mains connectionTransformer
LNN
`
L
`
max.
100 mA
ChainTrack
Fig. Connection diagram,
ceiling control unit
Button
+24 V DC
COM
24 V DC/
max. 25 W
GND
external device
24 V/max. 100 mA (500 mA*)
gn
+
rt
-
wh
gn
+12 V
br
12 V/max.100 mA
Optional
Fig. Connection diagram,
motor carriage*
Supply of external accessories
OSE
8K2
* The version can vary depending on the type.
This means the use of accessories can vary.
When connecting external devices, power-saving mode must be deactivated to ensure the power supply.