Installation Instructions

67
46900V001_Rev-D_EN
15. Maintenance and care
WARNING
Danger due to hot surfaces!
After frequent operation parts of the
motor carriage or the control unit may
become hot. If the cover is removed and
hot parts are touched, they may cause
burns.
Allow the operator to cool down before
removing the cover.
NOTE
The motor carriage is supplied with safety
low voltage via the chain and the track.
The use of oil or grease will greatly reduce
the conductivity of the chain, track and
motor carriage. This may result in faults
due to inadequate electrical contact.
The chain and track are maintenance-free
and must not be oiled or greased.
NOTE
The use of unsuitable cleaning agents may
damage the surface of the operator.
Clean the operator with a dry lint-free cloth
only.
15.2 Maintenance schedule
How
often?
What? How?
Once a
month
Test the
emergency
release
See Chapter "14.7
Function of the
emergency release"
Test obstacle
detection
See Chapter "13.1
Testing obstacle
detection"
Test photocell
Interrupt the active
photocell while the door
is closing. The door
must stop and open
slightly. If automatic
closing is activated, the
door opens completely.
If necessary, clean the
photocell, see Chapter
"15.3 Care"
Once a
year
Test the door
and all moving
parts
As directed by the door
manufacturer
Check screws
on door, ceiling
or lintel
Check that screws
are tight and tighten if
necessary
As needed
Chain and track Maintenance-free
Track
See Chapter
"15.3 Care"
Clean the
housing of the
ceiling control
unit and motor
carriage
See Chapter
"15.3 Care"