13. Function test/Final test
INFORMATION
After installation of the operator, the
person responsible for the installation
of the operator must complete an EC
Declaration of Conformity for the door
system in accordance with Machinery
Directive 2006/42/EC and apply the CE
mark and a type plate. This documentation
and this installation and operating manual
for the operator must be handed over to
the user.
This also applies if the operator is
retrotted to a manually operated door.
INFORMATION
Reversing: The operator stops when it
meets an obstruction and then moves in
the opposite direction for a short distance
to free the obstruction.
In the automatic closing function the
door opens completely if an obstacle is
detected.
INFORMATION
The operating forces can be modied and
adjusted with SOMlink and a WiFi-enabled
device. For more information ask your
specialist dealer.
After successful testing of the force settings, the obstacle
detection and the functions, the qualified specialist must
issue the EC Declaration of Conformity and attach the
CE mark and type plate to the door system.
The operator must reverse in the door OPEN direction
when it is loaded with a weight of 20 kg. The weight is
fastened in the centre of the bottom edge of the door for
this purpose.
The door must reverse during the door CLOSE
movement if it hits a 50-mm-high obstacle on the ground.
1. Open the door with the operator.
2. Place a 50-mm-high object in the centre of the door.
50 mm
Fig. Example: Obstacle detection on sectional door
3. Close the door with the operator.
⇒ If the door hits an obstacle, the operator must
immediately reverse.
⇒ The door opens completely at a pulse from the
transmitter.
⇒ If the operator does not reverse, a position reset
is required, see Chapter "10.13 Resetting the
control unit". The positions and the forces must
be reprogrammed.
13.2 Handover of door system
The qualified specialist must instruct the user:
• on the operation of the operator and its dangers
• on the handling of the manual emergency release
• on the regular maintenance, testing and care
measures which the user can carry out, see Chapter
"15. Maintenance and care"
• on the troubleshooting measures which the user can
carry out, see Chapter "16. Troubleshooting"
The user must be informed about which work must only
be performed by a qualified specialist:
• installation of accessories
• settings
• regular maintenance, testing and care, with the
exception of that described in Chapter
"15. Maintenance and care"
• troubleshooting, except that described in Chapter
"16. Troubleshooting"
• repairs
The following documents for the door system must be
handed over to the user:
• the installation and operating manuals for the
operator and the door
• inspection book
• EC Declaration of Conformity
• handover protocol for the operator