Installation Instructions
56
46900V001_Rev-D_EN
5. Attach the sticker "ACCU INSIDE" sticker to the
outside of the housing in a highly visible place.
6. Run a function test.
⇒ Pull the power plug out of the power outlet.
⇒ The operator is powered by the accumulator.
7. Press the button on the handheld transmitter.
⇒ Operator opens or closes the door at reduced
speed.
8. Connect the operator to the mains voltage.
Check that the power supply is connected.
Removing the accumulator
The accumulator is removed in the reverse order,
see Chapter "11.11 Installing and removing the
accumulator", section "Installing the accumulator".
DANGER
Danger of hazardous substances!
Improper storage, use or disposal of
accumulators, batteries and operator
components are dangerous for the
health of humans and animals. Serious
injury or death may result.
► Accumulators and batteries must be
stored out of the reach of children and
animals.
► Keep accumulators and batteries away
from chemical, mechanical and thermal
inuences.
► Do not recharge old accumulators and
batteries.
► Components of the operator as well as
old accumulators and batteries must not
be disposed of with household waste.
They must be disposed of properly.
NOTE
Dispose of all components in accordance
with local or national regulations to avoid
environmental damage.
INFORMATION
All operator components that have been
taken out of service must not be disposed
of with household waste, as they contain
hazardous substances. The components
must be disposed of correctly at an
authorised recycling centre. The local and
national regulations must be observed.
INFORMATION
Old batteries and battery packs must not
be disposed of with household waste as
they contain hazardous substances. These
must be disposed of properly at municipal
collection points or in containers provided
by dealers. National guidelines must be
observed.
11. Connections and special functions of the ceiling