46900V001_Rev-D_EN
or to prevent unintentional activation with a handheld
transmitter.
The following functions are deactivated in the factory
settings when the lock button is activated:
• Radio (handheld transmitter)
• Senso ventilation function
• Control device (corded external button)
To lock:
The button (2) on the wall station lights up green when
the operator is unlocked. The button (2) lights up red
when the operator has been locked by the wall station.
1. Press and hold the button (3) for at least 5 seconds
with the door closed.
⇒ Button(2)ashesgreen.
⇒ After 5 seconds, the button (2) lights up red.
⇒ Locking function activated.
⇒ All the functions of the operator are locked.
INFORMATION
If the door was still open, it can be closed
using the handheld transmitter. Only then
are all operator functions locked.
To unlock:
1. Press the button (3) for at least 5 seconds.
⇒ Button(2)ashesred.
⇒ Button (2) lights up green.
⇒ Locking function deactivated.
⇒ All the functions of the operator are activated
again.
INFORMATION
All locking and unlocking functions can be
modied and adjusted with SOMlink and a
WiFi-enabled device. For more information
ask your specialist dealer.
11.8 Conex
Two corded external buttons can be connected to the
KEYPAD connection with the Conex accessory part.
The function of the external buttons can be configured via
DIP switch 1 of the ceiling control unit. The factory setting
of DIP switch 1 is OFF.
KEYPAD
1
Fig. Keypad connection
The Conex accessory part is plugged into the KEYPAD
slot, see separate "Conex" instructions.
DIP switches
of the ceiling
control unit ON
OFF
1
ON
1
23
4
• "Conex"
additional
circuit board
• T1denes
door OPEN
• T2denes
door CLOSE
• "Conex"
additional
circuit board
• T1 pulse
sequence
• T2 lighting
function/partial
opening
11.9 Output OC
The door status display can be shown with the Output OC
(open collector output) accessory part. Set DIP switch 2
on the ceiling control unit to ON.
P
AD
1
4
Fig. Relay slot for Output OC
The Output OC accessory part is plugged into the Relay
slot, see separate "Output OC" instructions.
11. Connections and special functions of the ceiling
control unit