Installation Instructions

52
46900V001_Rev-D_EN
11. Connections and special functions of the ceiling
control unit
5. Connect the cable of button 2 to the terminal block
for COM and Signal.
Button 2 is connected.
6. Set DIP switch 4 on the wall device to ON.
7. Plug in the connection cable for the button and for
the accumulator, if necessary.
8. Close the ceiling control unit in reverse order,
see Chapter "11.11 Installing and removing
the accumulator" and "7.2 Cover of the ceiling
control unit".
9. Supply the operator with the mains voltage.
Settings on the motor carriage
To determine the partial opening door position, the
following settings must be made on the motor carriage.
1. Close the door completely up to the door CLOSE
end position.
2. Open the motor carriage, see chapter "7.1 Cover of
the motor carriage".
3. Set DIP switch 2 on the motor carriage to ON.
4. Press button 2 for the partial opening function.
The door moves in door OPEN direction.
5. Press button 2 again for the desired position for
stopping.
The door stops at the desired position.
11.5 Deleting partial opening
1. Set DIP switch 2 on the motor carriage to OFF.
2. Open the door completely up to the door OPEN end
position.
Partial opening is deleted.
To program a new position, see Chapter "10.17 Setting
partial opening".
11.6 Photocell and frame photocell
A 2-wire photocell from SOMMER or a 4-wire photocell
can be connected to the control unit. The control unit
automatically detects which version it is and sets itself to
that version.
Fig. Terminal for a 2-wire photocell
WL
24V/1A
Signal
COM
GND
+24V
O
12
WL
2
4V
/
1
A
O
1
2
Fig. Terminal for a 4-wire photocell
INFORMATION
If a photocell is retrotted on a programmed
system, the control unit must be reset, see
Chapter "10.13 Resetting the control unit."
INFORMATION
If a photocell is used, it must not be
triggered when starting the programming.
If a photocell is used as a frame photocell
on the door, move the door to the centre
position.
INFORMATION
During commissioning, the frame photocell
must not be interrupted by persons or
objects.
Frame photocell
1. Install the frame photocell in the frame, see separate
"Frame photocell" installation instructions.
2. Align the frame photocell and connect to the ceiling
control unit.