Installation Instructions
26
46900V001_Rev-D_EN
⇒ The entire chain is attached.
10 mm 17 mm 17 mm
Fig. 8 Fig. 9
8. Tension the chain to the mark on the plug-in unit,
see arrow in the detailed view.
9. Screw the two header brackets to the plug-in unit
with bolt and nut.
13 mm
B
ACK
H
INT
EN
100 mm -
700 mm
Fig. 10 Fig. 11
10. Turn the track to install the ceiling bracket.
The distance between the ceiling control unit and the
ceiling holder should be 100 - 700 mm.
Place the ceiling holder on the track and slide into
one another.
11. Fasten the perforated strips to the ceiling holder
on the right and left. Also observe the distances for
installation to the ceiling or lintel.
⇒ The track is prepared for the remainder of the
installation.
For further installation, see Chapter "6.4 Installation on
the door".
6.4 Installation on the door
X
5 -
65 mm
min. 35 mm
X
Fig. 1.1 Highest point for one piece and up-and-over doors
X
5 -
65 mm
min.
35 mm
X
Fig. 1.2 Highest point for a sectional door
INFORMATION
If the distance between the ceiling and the
bottom edge of the track is greater than
245 mm, extend the ceiling holder with
additional perforated strips.
1. Measure the highest point of the door "X" depending
on the type of door:
Open the door and measure the closest distance
(min. 35 mm) between the top edge of the door and
the ceiling.
The distance between "X" and the bottom edge of
the track must be at least 5 mm and no more than
65 mm.
max. 30°
Fig. 2
6. Installation