6. Installation
Fig. 2
2. Open the door halfway.
⇒ The door must remain in this position.
⇒ The door must be moved easily by hand and must
be balanced.
If the door moves upwards or downwards by itself,
the weight balance of the door must be adjusted.
Emergency release
In a garage without a separate entrance (e.g. wicket
doors), the operator's emergency release must be
operable from outside. The emergency release must also
be routed to be accessible from the outside. This can
be done with a Bowden wire or a release lock. Ask your
specialist dealer.
Adjusting the top roll of a sectional door
Fig. Top roll on sectional door
If a manually operated sectional door is retrofitted with an
operator, the position of the top roll must be checked and
adjusted if necessary.
The top roll must be routed up over the curve.
6.3 Installation of the operator system
The operator may only be installed if the installation
requirements and dimensions below are correct.
NOTE
Specify the position for mounting the
operator on the door. Manually open and
close the door several times. The door
must be moved easily.
A manual movement force of 150 N is
applicable for private garage doors and
260 N for commercial doors.
The value is applicable for the entire life of
the door. The door must also be maintained
and inspected as specied by the door
manufacturer.
Fig. 1
CAUTION
Risk of injury to hands!
Rough metal parts may cause abrasions
and cuts when picked up or touched.
► You must wear safety gloves when
working with rough metal parts.
1. Open the package.
Place the two cartons in the package beside the
tracks and open them.
Check the entire contents against the scope of
delivery, see chapter "3.5 Scope of delivery".