User's Manual
Table Of Contents
55en
Troubleshooting
Disconnect the opener from the power (switch off the cir-
cuit breaker to the opener or disconnect the fuse on the
circuit supplying the opener with voltage) and check to be
sure no voltage is present.
Remove both lamp lenses (1). Press each of the lugs (2) in
the direction of the lamp lens.
Unscrew both light bulbs in a counterclockwise direction.
Remove the covering (1). Slide the covering in the direc-
tion of the arrow.
Tighten the screw (1) with a small Phillips screwdriver.
Open the controller housing cover downwards (2) and
unhook the (3) fastening.
1
2
3
2
1
14
15
16
Radio
Powe r
Status
Safety
Command
Reset
Learn
13
3
4
5
6
1
Replace the defective fuse (1) (fuse T 10 A, 250 V). Fuse
dimensions 1/4” x 1-1/4” (6.35 x 32 mm).
Attach the controller housing covering (1) to the side facing
the C-rail and fold it up.
Tighten the screw (2) with a small Phillips screwdriver.
Slid on the covering (1) in the direction of the arrow.
Screw in both light bulbs (2) in a clockwise direction.
2
1
14
15
16
Radio
Power
Status
Safety
Command
Reset
Learn
13
3
4
5
6
1
2
“clic”
1
14
15
16
13
1
222
T 10 A, 250 V
1