User's Manual Part 2

108 Part ######A revision 00a-DRAFT March 29, 2006
Macro Base Station Installation Procedures (NPM-1000)
To configure the Ethernet switches
1 Establish a serial connection with the Ethernet switch:
i Connect a PC to the Ethernet switch using the supplied RJ-11 to DB-9 serial cable with a null
modem adapter. See Table 6.4 for pin assignments.
ii Start a serial terminal session using the settings shown in Table 6.5.
2 Log in to the Ethernet switch.
3 Restore the default settings for the Ethernet switch by typing:
switch defaults
The Ethernet switch reboots.
4 Log in to the Ethernet switch.
5 Configure the switch by typing:
port config 1-4 off 100 full false
port config 5-22 off 100 half false
span port enable 1-26 on
span port fast 5-24 on
bootp enable off
dhcp server enable off
dhcp client enable sw0 off
cos queuing algorithm strict
cos queuing map 0 0
cos queuing map 1 0
cos queuing map 2 0
cos queuing map 3 0
cos queuing map 4 1
cos queuing map 5 2
cos queuing map 6 3
cos queuing map 7 3
gvrp enable off
ip config sw0 switch_ip_address 255.255.255.192 1
ip gateway router0-0_ip_address
ip forward off
tftpd sessions 0
where:
switch_ip_address
is the IP address of the Ethernet switch you are configuring
router0-0_ip_address
is the IP address of the primary router
6 Change the default password:
i Type:
Parameter Setting
Baud 9600 bits/s
Data bits 8
Parity None
Stop bits 1
Flow control None
Table 6.5
Ethernet Switch Serial Port Settings