User's Manual Part 2
88 Part ######A revision 00a-DRAFT March 29, 2006
Macro Base Station Installation Procedures (NPM-1000)
Connect the RF Cables
The RF cables are 0.195-inch coaxial cables with male SMA connectors on each end.
Component Numbering
The RF shelves are numbered from bottom to top (that is, the bottom shelf is “0” and the top shelf is
“2”). When viewed from the front of the base station, the RFSS modules in each shelf are numbered
from left to right (that is, the left module is “0” and the right module is “3”).
The radio shelves are numbered from bottom to top (that is, the bottom shelf is “0” and the top shelf
is “2”). Each radio shelf contains two IF/RF cards, one in slots 10–11 and one in slots 15–16.
Figure 4.18 shows the layout of the RFSS modules and IF/RF cards.
Figure 4.18
RF Connector Locations
RFSS
[TT LNA]
Rx
Tx
SGNL
FAIL
ACTIVE
FUSE
0
Rx
00558
123
0123
0123
Utility shelf
RF Shelf #0
RF Shelf #1
RF Shelf #2
Radio Shelf #2
Radio Shelf #1
RX MAIN
RX DIV
TX MAIN
TX DIV
Radio Shelf #0
Tx
IF/RF Card
RFSS Module
NPM Racks (Front View)