User's Manual Part 2
March 29, 2006 Part ######A revision 00a-DRAFT 77
Chapter 4: Base Station Installation Procedures
Cover Unused Card Slots
Any empty slots in the radio and utility shelves should be covered with filler panels. The filler panels
ensure airflow to the other cards and protect the cards from dust and electromagnetic interference.
To cover the unused slots with filler panels
1 Remove the filler panel from its protective bag.
2 Set the two ejector handles on the filler panel in the open position by turning the handles away from the
center of the front panel.
In the open position, the ejector handles are at an approximately 45° angle from the front panel.
3 Ensure that the mounting screws are withdrawn enough to allow for the insertion of the filler panel.
Single-slot filler panels have two mounting screws, one located under each ejector handle. Double-slot
filler panels have four mounting screws, one located under each ejector handle and one located beside
each ejector handle.
4 Orient the filler panel so that the guide pins are on the right-hand side of the ejector handles.
5 Slide the filler panel into the slot. The guide pins should slide into the round holes located at the top and
the bottom of each slot on the right-hand side. Apply sufficient pressure to fully mate the filler panel with
the shelf.
6 Lock the filler panel in the slot by turning the handles towards the center of the front panel.
In the lock position, the ejector handles are at a 90° angle from the front panel.
7 Secure the filler panel in the slot by installing the 2.5-mm mounting screws. Torque each screw to 4
inch-pounds.
8 Ensure that the filler panel is secure by grasping both ejector handles and pulling lightly. The filler panel
should not move.
If the filler panel does move, ensure that the mounting screws are attached to the shelf frame. If
necessary, remove the panel and repeat this procedure.