User's Manual Part 1
March 29, 2006 Part ######A revision 00a-DRAFT 53
Chapter 4: Base Station Installation Procedures
A
TTACHING
G
ROUND AND
P
OWER
C
ABLES
These procedures describe how to ground and power the base station.
Procedure Page
Check PDP Sector Configuration 54
Ground the Racks 55
Attach the Main and Return Power Cables 57
WARNING: Ensure that all of the circuit breakers on each power distribution panel
(PDP) are in the OFF (down) position before attaching any cables. Failure to do so may
result in personal injury and cause damage to or destruction of the base station.
Access to the ground and power terminals is prevented by the rear cover of the PDP.
The rear cover should always be attached to the PDP during base station operation.
This prevents foreign objects from accidently coming into contact with the live wires and
causing a short.