User Manual
December 16, 2002 Part 003609A revision 01 79
Chapter 4: Installation Procedures
Cover Empty RFSS Slots
Any empty slots in the RF shelves should be covered with RFSS filler panels. The
RFSS filler panels protect the other RFSS modules from dust and ensure the
required air flow to the installed RFSS modules.
To cover unused slots with RFSS filler panels
1 Remove the RFSS filler panel from its protective bag.
2 Orient the filler panel so that the text on the front panel is right-side up.
3 Secure the filler panel over the RFSS slots using four #2 Phillips screws, one on
each corner. Torque the screws to 12 inch-pounds.
4 Ensure that the filler panel is secure by grasping the handle on the front panel and
pulling lightly. The filler panel should not move.
If the filler panel does move, ensure that the mounting screws are attached to the
RF shelf assembly. If necessary, remove the filler panel and repeat this procedure.
5 Repeat steps 1 to 4 until all the empty slots are covered with filler panels.