To configure the application hosts
1 Remove the application hosts from their antistatic packaging at a grounded work
area. Ensure that you are properly grounded with a wrist or boot strap before
handling the cards. Depending on the configuration of your basestation, you may
have up to eight application hosts that need to be configured.
2 On each card, set SW3-3, SW3-4, and SW2-4 to the closed (ON) position. Figure
C.1 shows the locations of the switches.
Figure C.2
Application Host Switch Configuration
3 Ensure that the other switches are configured as shown in Table C.2.
4 Place the cards back in their antistatic packaging until you are ready to install them
in the shelves.