User Manual
118 Part 004071A revision 00b August 6, 2003
Amosphere NPM Installation Procedures (MMDS)
If the basestation has already been configured in the OAMP software, the
basestation will automatically start its call processing and enable the SOMA Air
Interface. Any SOMAports powered on within the supported sectors will acquire
the basestation and establish a connection.
If the basestation has not been configured in the OAMP software, the red error
lights on the PDPs and the RFSS modules will light up. The basestation will not
enable the SOMA Air Interface.
6 After powering on the basestation, proceed to Chapter 6, “On-Site Software
Installation and Configuration Procedures” for procedures on optimizing the cards.
RFSS Module Circuit Breaker
RF shelf 0, RFSS module 0 RF rack PDP, CB 02
RF shelf 0, RFSS module 1 RF rack PDP, CB 03
RF shelf 0, RFSS module 2 RF rack PDP, CB 04
RF shelf 0, RFSS module 3 RF rack PDP, CB 05
RF shelf 1, RFSS module 0 RF rack PDP, CB 06
RF shelf 1, RFSS module 1 RF rack PDP, CB 07
RF shelf 1, RFSS module 2 RF rack PDP, CB 08
RF shelf 1, RFSS module 3 RF rack PDP, CB 09
RF shelf 2, RFSS module 0 RF rack PDP, CB 10
RF shelf 2, RFSS module 1 RF rack PDP, CB 11
RF shelf 2, RFSS module 2 RF rack PDP, CB 12
RF shelf 2, RFSS module 3 RF rack PDP, CB 13
Table 5.2
RFSS Module Circuit Breaker Summary
installation.book Page 118 Wednesday, August 6, 2003 6:06 PM