User Manual
11
Configuration commands
Command
CE(eE)<CR>
Description
- The command for transmitting extended CAN frame can be changed.
- If you change to the command that already exists, CS-CAN may not operate
properly. Please be advised before changing commands.
Example
When CS-CAN takes CESV<CR> command,
SlllLDD... <CR> can be used instead of tlllLDD...<CR>.
VlllL<CR> can be used instead of TlllL<CR>.
Command
H(R)<CR>
Description
- Check if CAN frame was transmitted successfully by getting reply from RS232.
- After the setting is complete, when transmission of CAN frame is compete,
RS232 takes OK<CR> message.
- R Response
0: Disable 1: Enable
Example
When CS-CAN takes H1<CR> command, it will send CAN frame and set RS232
to be ready to send OK<CR>.
Command
SV<CR>
Description
- Save all modified configuration
- You must save your settings after modifying.
Example
When CS-CAN takes SV<CR> command, it will save all settings to the Flash
memory.