User Manual

10
Configuration commands
Command
WS(BSP)<CR>
Description
- This command sets environment for RS232 communication.
- B Baud rate
0: 1200bps 1: 2400bps 2: 4800bps
3: 9600bps 4: 14400bps 5: 19200bps
6: 38400bps 7: 57600bps 8: 115200bps
- S Stop Bit
0: 1bit 1: 2bits
- P Parity Bit
0: None 1: Odd 2: Even
3: Mark 4: Space
Example
When CS-CAN takes WS300<CR> command, it will set Baud rate in RS232 to
9600bps, stop bit to 1, and parity bit to none.
Command
CS(tT)<CR>
Description
- The command for transmitting standard CAN frame can be changed.
- If you change to the command that already exists, CS-CAN may not operate
properly. Please be advised before changing commands.
Example
When CS-CAN takes CSSV<CR> command,
SlllLDD... <CR> can be used instead of tlllLDD...<CR>.
VlllL<CR> can be used instead of TlllL<CR>.