Operation Manual

Starting / Stopping the engine; Operation hints
ENGLISH 11
10. Starting / Stopping the engine
1. Open fuel valve (ON).
2. Push primer (Fig A) until float-chamber is filled
with fuel (only when engine is cold).
3. Open throttle lever to half position (Pos.
START).
4. Close choke (Fig. 7 - B)
only when engine is cold.
5. Start engine with recoil starter. DO NOT yank
starter suddenly; first pull starter rope until
pawls engage (resistance of recoil spring is
felt). Lead starter grip slowly back to starter
housing.
6. Open choke as soon as the engine fires
and "tries" to start. Repeat the starting
procedure if required.
Stopping the engine:
Push throttle lever past minimum (idling) position
to STOP position. Close fuel tap (OFF).
11. Operation hints
Before every use and before every start of the
mistblower check and ensure the machine is in
good and safe condition. (throttle operation,
ignition switch, safety devices, shoulder strap
and check for fuel leaks)
During the starting procedure and while
operating the mistblower, the operator must
have secure footing and have a safe body
position.
The engine starting site should be at least 3
meters away from the refueling site.
11.1 Spraying
To open on tap:
Move lever upwards into position "I".
To shut off tap:
Move lever into horizontal position "O". When
shutting tap, move lever slowly against spring
tension to position "0". Do not let the lever flick
back.
Note:
For spot spraying (treatment of single plants or
smaller area), push the lever momentarily into
position "2" (spot spraying).
The correct output is obtained according to
dosage-sleeve setting
When spraying predominantly upwards (tall trees)
we recommend using the liquid pump offered as an
accessory (part no.: 44 00 117)
Fig. 8
Fig. 7
Fig. 9