10 Maintenance plan / 11 Standard delivery
ENGLISH 17
10 Maintenance plan
Before you start working
After work
When changing the spraying agent
On demand
Monthly
Annually or at the start of the season
Entire pressure sprayer
Check whether the device is safe to use:
Visual inspection of the device
Check the tightness of all equipment compo-
nents (at maximum permissible pressure with
open and closed shut-off valve)
Check the function of all active components
(shut-off valve, pump toggle switch, pressure
gauge (depending on the model))
X
Hoses and their screw
connectors
Visual inspection X
Spraying agent tank Visual inspection X
Clean (section 9.8) X X
Nozzles and
ball valve filter
Clean (section 9.8) X X X
Trial run to check the spray nozzles and the
ball valve filter by measuring the delivery rate
(section 9.3)
X*: A monthly trial run is required only if the
device is used frequently.
X X* X
Filling strainer Visual inspection X
Clean (section 9.8) X X X
Cap gasket Grease (section 9.7) X X
Rechargeable battery
(and the spare battery if
you have one)
Recharge (section 6.3) X X
Never start working if there are any irregularities or leaks, if you can see any damage to the equipment
(including the support frame), if any of the adjustment settings are incorrect or if the equipment is not
working properly in any way. In this event have the device checked by an autorised SOLO workshop.
If you have any questions please refer to your authorised SOLO dealer.
11 Standard delivery
Standard device with shut-off valve assembled on the high-pressure hose
Spray tube with assembled nozzle attachment
Charger with mains cable / EURO plug and 3 mains plug adapters for different countries
Sticker for the spraying agent tank: herbicide, fungicide and insecticide
These operating instructions, the EC declaration of conformity on a separate piece of paper