Datasheet_Solis-1P(6-10K)-4G-US
Datasheet
Model
Solis-1P6K-4G-US Solis-1P7K-4G-US Solis-1P7.6K-4G-US Solis-1P8K-4G-US Solis-1P8.6K-4G-US Solis-1P9K-4G-US Solis-1P10K-4G-US
DC Values
Max. DC input power (watts) 7200 8400 9100 9600 9900 10800 11500
Max. voltage (volts) 600
Rated voltage (volts) 330
Startup voltage (volts) 120
Operating MPPT voltage range (volts) 100-500
Max. usable input current per MPPT (amps) 3*10 4*10
Max. short circuit input current (amps) 3*15.6 4*15.6
Number of MPPTs/Max. input strings number 3/3 4/4
AC Values
Nominal and max. output power 240V grid (watts) 6000 7000 7600 8000 8600 9000 10000
Nominal and max. output power 208V grid (watts) 6000 7000 7600 8000 8600 9000 9000
Nominal grid voltage (volts) 240/208
Nominal grid frequency (hertz) 60
Operating phase Single Phase
Max. output current for 240V grid (amps) 25 29.2 31.7 33.3 35.8 37.5 41.7
Max. output current for 208V grid (amps) 28.8 33.7 36.5 38.5 41.3 43.3 43.3
Output power factor >0.99
Output power factor range 0.8 leading ... 0.8 lagging
Grid current THD <3%
Eiciency
Peak eiciency 97.8%
CEC weighted eiciency 97.5%
MPPT eiciency >99.5%
Protection
DC reverse-polarity protection Yes
AC short circuit protection Yes
AC output overcurrent protection Yes
Output overvoltage protection-Varistor Yes
Ground fault monitoring Yes
Grid monitoring Yes
Islanding protection Yes
Integrated AFCI (DC arc-fault circuit protection) Yes
Integrated DC switch Yes
Rapid shutdown Yes, Sunspec Certified Built-in Transmitter
Compliant MLRSD Products Solis-MLRSD-R(1-2)-1G, APSmart RSD-S-PLC
General Data
Dimensions (width*height*depth) 13.5*28.8*9.8in (342*732*249 mm)
Weight 45.2lbs (20.5 kgs) 45.6lbs (20.7kgs)
Topology Transformerless
Internal consumption <1W (night)
Ambient operating temperature range -13°F to 140°F (-25°C to 60°)
Enclosure type NEMA 4X
Noise emission (typical) <30dB(A)
Cooling concept Natural convection
Max. operating altitude without derating 13, 120 (4000m)
Designed lifetime >20years
Compliance
L 1741, UL 1741 SA, Rule 21 Phase I and II compliant (ready for Phase III), UL 1998, UL 1699B, IEEE 1547,
FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1
Features
RGM Optional
Communication protocol Modbus RTU (Sunspec compliant)
Communication Optional cellular and Wi-Fi
Connections 2 knockout for 1"conduit at bottom, 4 knockout for3/4"conduit at side and back
Display LCD-2×20 Z
Warranty 10 Years standard (extendable to 20 years)