Solis_Manual_RHI-1P(5-10)K-HV_USA_V1,1
8. Specifications8. Specifications
Rated output power
10kW
Max. apparent output power
10kVA
Output AC(Grid side)
Power Factor
Max efficiency
EU efficiency
>0.99 (0.8 leading - 0.8 lagging)
98.0%
97.5%
Max. output current
60.0A/60.0A
THDi
<3%
Efficiency
Protection
Ground fault monitoring
Residual current mornitoring unit
Integrated AFCI (DC arc-fault circuit protection)
DC reverse polarity protection
Rapid Shutdown NEC 2017
Compliant MLRSD Products
Protection class/Over voltage category
Yes
Built-in MLRSD Sunspec Transmitter
APSmart RSD-S-PLC
I/II
AC grid frequency range
Rating grid output current
48.0A/41.7A
The grid voltage range
Rating grid frequency
183-228 V (for 208 V rated)/211-264 V (for 240 V rated)
60 Hz
Operation phase
Rated grid voltage
1Ф/PE
208V / 240 V
Yes
Yes
Yes
Grid connection standard
Safty/EMC standard
2000m
Max.operation altitude
Dimensions(W/H/D)
20.2*28.1*8.18 in (539*717*250 mm)
-25~+60 ℃/-13~+140 ℉
Weight
Operation temperature range
Ingress protection
NEMA 4X
General data
66.1 lbs (30 kg)
Transformerless
Topology
<30 dB (A)Noise emission
Natural convection
Cooling concept
Features
3 knockout for 1'' conduit at side and bottom,
Screw clamp terminal (Max. 7 AWG)
AC connection
Communication
Warranty
RS485, Optional:Wi-Fi, GPR S
10 years standard (Extand to 20 years)
Display
7.0"LCD color screen display
2 knockout for 1'' conduit at side and bottom,
Fuse screw terminal
DC connection
Compatible batteries
BYD B-Box H5.0/7.5/10, LG Chem RESU10H Type R
.70. .71.
59.5 Hz-60.5 Hz
IEEE1547A, UL 1741 SA, ISO-NE, CA Rule 21 phase III
UL 1741 CRD, IEEE 1547, UL 1699B, UL 1998, UL 9540,
CAN/CSA C22.2.107.1-1, FCC, Part 15 Class B, SRD-UL1741