Solis_Manual_RHI-1P(5-10)K-HV_USA_V1,1

5. Operation 5. Operation
The software update includes the HMI and DSP. Corresponding firmware version
can be checked in this setting. Press “ENT” to enter the upgrading mode.
5.6.7 Software Update
Figure 5.56 Software Update
SettingsSoftware Update
2015-02-23 19 35
HMI Update
DSP Update
Y E S =< E N T > N O = < E S C >
5.6.8 Export power Set
This function is to set the export power control.
1.Backflow Power. 2. ON/OFF. 3.Failsafe ON/OFF
Setting 1 and 3 are only valid when Setting 2 is set to "ON"
Settings
Export power Set
2015-02-23 19 35
BackowPower
ON/OFF
FailSafe ON/OFF
Figure 5.57 Export power Set
Figure 5.58 Backflow Power
Settings
Backow Power
2015-02-23 19 35
Y E S =< E N T > N O = < E S C >
Backow Power+1200W
E S C
U P
D O W N E N T
Determine the allowed backfeed power. (System export to the grid)
5.6.8.1 Backflow Power
5.6.8.2 ON/OFF
Figure 5.59 ON/OFF
Settings
ON/OFF
2015-02-23 19 35
ON
OFF
Y E S =< E N T > N O = < E S C >
Enable/Disable the function.
.54. .55.