Solis_Manual_RHI-1P(5-10)K-HV_USA_V1,1

4. Installation
.17..16.
4.6.1 Meter Communication
Communication Terminals: MTR485B and MTR485A.
Figure 4.10 Meter terminals
4. Installation
The Solis RHI-HV 5G series inverter integrates export power control function
which requires an external meter to detect the power flow.
The following figure shows the corresponding connection of the meter.
GRID
Figure 4.7 Meter (AGF-AE-D)
PV strings
Battery
RHI-1P10K-HVES-5G
Note:
The battery fuses in the wiring box are replaceable.
The replacement must be done by Solis authorized technicians only.
Fuse specification: 600V, 30A.
Note:
Before connecting the battery, please carefully read the user manual of the
battery and perform the installation exactly as the battery manufacturer
requests.
4.6 Communication Terminals
From left to right, the communication terminals consist of ten ports.
Figure 4.9 Communication port
CANL
CANH
ENABLE
GND
BMS485B
BMS485A
RS485B
RS485A
MTR485B
MTR485A
Inner
External
A B
Symbol
CANL
CANH
ENABLE
GND
BMS485B
BMS485A
RS485B
RS485A
MTR485B
MTR485A
Table 4.4 communication terminals
Wire Requirement
22-16AWG
Recommend:18AWG
Exposure length: 11mm
Comments
Battery communication
depends on different
battery types.
Refer to Section 4.6.2 for
details.
RS485 Communication
Meter Communication
NO.
1
2
3
4
5
6
7
8
9
10
Cable connection steps:
1. Use slot type screwdriver to press the block on the top.
2. Insert the exposed copper part of the cable into the terminal.