Technical Manual

40
4. Transshipment Firmware Configuration
4.1 Parameters of the Transshipment Firmware Configuration
Every MAG 100 Transshipment firmware will be accompanied by the “Config.txt” file
which has all the current settings of the firmware. In this section will be explained
every parameter and its use on the computer on board.
TRANSSHIPMENT
APP DESCRIPTION
MODOTESTE
Defines the Firmware test mode.
0: Test Mode disable.
1: Test Mode activated (with the ED4
active, a fixed speed of (5Km/h) and RPM
of 640 (Engine on).
FUT
Defines the activation of the FLOW app on
Firmware.
0: FLOW app disables.
1: FLOW app active.
ATIVACCT
Defines the activation of the CDT app on
the Firmware.
0: Applicative CDT disable (identifies the
harvester and changes the status. It
doesn’t send lifting register ZIG22).
1: App CDT active
ATIVACCTPLANTIO
Defines the activation of the CCT
PLANTING app on the Firmware.
0: CCT PLANTING APP disable.
1: CCT PLANTING APP active.
SEMCOORD
Defines the activation of the Transshipment
Coordinator Function.
0: Disables the Transshipment Coordinator
Function.