Installation and Operation Manual
Confidential & Proprietary 48/57 Alliance-TR
Environmental Data
Environmental Condition & IP Rating
Satisfy IP66 standards
Operating Temperature (°C)
-25° ~ +55°C
(** -25° ~ +50°C when two 20W HRDUs and two
40W HRDUs are installed)
Operating Humidity
5~ 90% non-condensing
6.2. Electrical Specifications
Part Name
Service
Band
Downlink (Tx)
Uplink (Rx)
Freq.
(MHz)
Bandwid
th
(MHz)
Output
Power
(dBm)
Freq.
(MHz)
Bandwidth
(MHz)
TR_HRDU_900
GSM 900
UMTS 900
LTE 900
925~960
35
40 (GSM 900)
880~915
35
43 (UMTS
900)
43 (LTE 900)
TR_HRDU_A_U2100
UMTS 2100
LTE2100
2110~2170
60
43
1920~1980
60
TR_HRDU_U2100_B
UMTS 2100
LTE 2100
2110~2170
60
43
1920~1980
60
TR_HRDU_A_1800
GSM 1800
LTE 1800
1805~1880
75
40(GSM)
1710-1785
75
43(LTE)
TR_HRDU_1800_B
LTE 1800
1805~1880
75
43
1710-1785
75
TR_HRDU_L2600F
LTE 2600
2620~2690
70
43
2500~2570
70
TR_HRDU_L2600F_B
LTE 2600
2620~2690
70
43
2500~2570
70
TR_HRDU_L800
LTE 800
791~821
30
43
832~862
30
TR_HRDU_L800_B
LTE 800
791~821
30
43
832~862
30
TR_HRDU_L2300T
LTE2300
2300~2400
100
43
2300~2400
100
TR_HRDU_L2600T_40W
LTE TDD 2600
2575-2615
40
45
2575-2615
40