User's Manual

Confidential & Proprietary 6/35
“Only qualified personnel should handle the DAS equipment. Any person involved in
installationorserviceoftheDASshouldunderstandandf ollowthesesafetyguidelines.”
‐Obeyallgeneralandregionalsafetyregulationsrelatingtoworkonhighvoltageinstallations,aswellas
regulationscoveringcorrectuseoftoolsandpersonalprotectiveequipment.
- The powersupplyunit inrepeaterscontains dangerous voltagelevel, whichcancause electricshock.
Switch the mains off prior to any work in such a repeater. Any local regulations are to be followed
whenservicingrepeaters.
‐Topreventelectricalshock,switchthemainpowersupplyoffpriortoworkingwiththeDASSystemor
FiberBDA.Neverinstalloruseelectricalequipmentinawetlocationorduringalightningstorm.
‐Whenworkingwithunitsoutdoors,makesuretosecurelyfastenthedoororcoverinanopenposition
topreventthedoorfromslammingshutinwindyconditions.
‐Usethisunitonlyforthepurposespecifiedbythemanufacturer.Donotmodifyorfitanyspareparts
thatarenotsoldorrecommendedbythemanufacturer.Thiscouldcausefires,electricshockorother
injuries.
‐AnyDASsystemor FiberBDAwill generateradio(RF)signalsand continuouslyemitRFenergy.Avoid
prolonged exposure to the antennas. SOLiD recommends maintaining a 200cm minimum clearance
fromtheantennawhilethesystemisoperating.
‐Donotoperatethisunitonorclosetoflammablematerials,astheunitmayreachhightemperatures
duetopowerdissipation.
‐Donotuseanysolvents,chemicals,orcleaningsolutionscontainingalcohol,ammonia,orabrasiveson
theDASequipment.Alcoholmaybeusedtocleanfiberopticcablingendsandconnectors.
‐Donotlookintotheendsofanyopticalfiberordirectlyintotheopticaltransceiverofanydigitalunit.
Use an optical spectrum analyzer to verify active fibers. Place a protective cap over any radiating
transceiveroropticalfiberconnectortoavoidthepotentialofradiationexposure.
‐Allowsufficientfiberlengthtopermitroutingwithoutseverebends.
‐Forpluggableequipment,makesuretoinstallthesocketoutletneartheequipmentsothatitiseasily
accessible.
‐Certification
FCC:ThisequipmentcomplieswiththeapplicablesectionsofTitle47CFRParts15,22,24,27and90
UL/CUL: This equipment complies with UL and CUL 19501 Standard for safety for information
technologyequipment,includingelectricalbusinessequipment
FDA/CDRH: This equipment uses a Class 1 LASER according to FDA/CDRH Rules.This product
conformstoallapplicablestandardsof21CFRChapter1,SubchaperJ,Part1040