User's Manual

Confidential & Proprietary 14/59
3.1 System specifications
3.1.1 Physical Specifications
Parameter HMRU HARU
RF Connectors
3N-type,female
6SMBL, female
1N-type,female
2SMBL, female
Serial Interface connector
1 RS-232 9-pin
D-sub, male
1 RS-232 9-pin
D-sub, male
Fiber connector 1 SC/APC -
LED Alarm and
Status Indicator
System status
z Power on status
z TX Communication
z RX Communication
z LD status
z PD status
z ALM status
System status
z Power on status
z TX Communication
z RX Communication
z LD status
z PD status
z ALM status
AC Power
Normal Range: 120VAC 50/60Hz
Operating range
108~132VAC,50/60Hz
Normal Range: 120VAC 50/60Hz
Operating range
108~132VAC,50/60Hz
Power consumption
50W
Common part only
40W
Common part only
Enclosure Dimensions 360 x 700 x 280mm 360 x 700 x 280mm
Weight[Common part] 28Kg 27Kg
3.1.2 Optic wavelength and Laser power
Parameter HROU Remark
Wavelength
TX: 1550nm
RX: 1310nm
Output power 7dBm±1dBm to ODU
3.1.3 Environmental specifications
Parameter HMRU,HARU Remark
Operating Temperature
-30 to +55
°C
Operating Humidity 5% to 90%,Non-condensing