User's Manual

Confidential & Proprietary 103/139
FULL
74W Both HPA ON
RDU 850C+700LTEC
850C 49W 700LTEC HPA OFF
700LTEC
58W
850C HPA OFF
FULL 93W Both HPA ON
RDU 700LTEF SISO
32W
RDU 700LTEF MIMO 50W
SISO & MIMO
HPA ON
RDU 700LTEF+850C 90W Both HPA ON
For power consumption of ROU, the common part consumes 17W. Depending on the
quantity of each RDU, you can add overall power consumption of ROU. Only, in case
of Dual-Band signals, power consumption is calculated respectively when HPA of the
other party is turned OFF and two HPA devices are turned ON. Note that when you
calculate Power Budget.
5.4 OEU Installation
OEU is used to expand ROU in Campus Site.
OEU is located at a Remote Closet. As it can be equipped with up to two DOUs, you
can expand a total of eight ROUs.
5.4.1 OEU Shelf installation
OEU is a shelf in around 2U size. Its width is 19” and so this unit should be inserted into a 19”
Standard Rack. OEU is in a Remote Closet, providing optical ports of ROU.
The following table shows power consumption of OEU:
No. Unit Description Remark
Common Part
Shelf
Including EWDM,ERF,EPSU,ECPU,
19”,2U
1EA
Power Cable -48Vdc Input with two lug terminal 1EA
Optional Part DOU Optical Module with 4 Optic Port
Up to 2EA to be
inserted