User's Manual

Confidential & Proprietary 98/139
FULL 93W Both HPA ON
1900P 46W AWS-1 HPA OFF
AWS-1 46W 1900P HPA OFF
RDU 1900P+AWS-1
FULL 68W Both HPA ON
VHF 47W VHF HPA OFF
UHF 47W UHF HPA OFF
RDU VHF+UHF
FULL 74W Both HPA ON
For power consumption of ROU, the common part consumes 17W. Depending on the
quantity of each RDU, you can add overall power consumption of ROU. Only, in case
of Dual-Band signals, power consumption is calculated respectively when HPA of the
other party is turned OFF and two HPA devices are turned ON. Note that when you
calculate Power Budget.
5.4 OEU Installation
OEU is used to expand ROU in Campus Site.
OEU is located at a Remote Closet. As it can be equipped with up to two DOUs, you
can expand a total of eight ROUs.
5.4.1 OEU Shelf installation
OEU is a shelf in around 2U size. Its width is 19” and so this unit should be inserted into a 19”
Standard Rack. OEU is in a Remote Closet, providing optical ports of ROU.
The following table shows power consumption of OEU:
No. Unit Description Remark
Shelf
Including EWDM,ERF,EPSU,ECPU,
19”,2U
1EA
Common Part
Power Cable -48Vdc Input with two lug terminal 1EA
Optional Part DOU Optical Module with 4 Optic Port
Up to 2EA to be
inserted