User's Manual

Confidential & Proprietary 114/136
After turning on the switch of the power supply in BIU, check information on each
module’s LED of the system. The table below shows normal/abnormal cases
depending on the status of each module’s LED.
LED information
Unit LED Indicates
MDBU
ON Green: MDBU is normally power-supplied.
ALM
Green: MDBU is normal.
Red: MDBU is abnormal; check the alarm through RS-232C.
MCPU
ON
Green: MCPU is normally power-supplied.
TXD
Green flicker: TX signals are transmitted to communicate with ROU.
RXD
Green flicker: RX signals are received from ROU.
ALM
Green: BIU system is normal.
Red: BIU system is abnormal; check the alarm through RS-232C.
MPSU
ON Green: BIU is connected with power and MPSU works normally.
ALM
Green: DC output is normal.
Red: DC output is abnormal.
MDBU Setting
Insert MDBU into BIU. Check if the “ON” LED Indicator at the front panel of MDBU is lit green.
Make connection with DEBUG port of MCPU through RS-232 Cable (Direct Cable).
Check if the ID of MDBU module is searched for in those 1~4 slots of MDBU through GUI.
When you select the tab of a corresponding slot (MDBU 1~4) from the main window, you can
inquire and set the status of a corresponding MDBU module.