User's Manual

Confidential&Proprietary91/115 SC‐DAS
Checkingthestatusofthesystem’sLEDIndicator
AfterturningontheswitchofthepowersupplyinBIU,checkinformationoneachmodule’s
LEDofthes ystem.Thetablebelowshowsnormal/abnormalcasesdependingonthestatus
ofeachmodule’sLED.
LEDinformation
Unit LED Indicates
MDBU
ONGreen:MDBUisnormallypower‐supplied.
ALM
Green:MDBUisnormal.
Red:MDBUisabnormal;checkthealarmthroughRS‐232C.
MCPU
ON
Green:MCPUisnormallypower‐supplied.
TXD
Greenflicker:TXsignalsaretransmittedtocommunicatewithROU.
RXD
Greenflicker:RXsignalsarereceivedfromROU.
ALM
Green:BIUsystemisnormal.
Red:BIUsystemisabnormal;checkthealarmthroughRS‐232C.
MPSU
ONGreen:BIUisconnectedwithpowerandMPSUworksnormally.
ALM
Green:DCoutputisnormal.
Red:DCoutputisabnormal.
MDBUSetting
Insert the MDBU into the BIU. Check if the “ON” LED Indicator at the front panel of MDBU is lit
green.MakeaconnectionwithDEBUGportoftheMCPUthroughUSBCable
CheckiftheIDofMDBUmoduleislocatedinthoseSISOMDBU#1&2,MIMOMDBU#1&2slots
ofthe
MDBUthroughtheGUI.Whenyouselectthetabofacorrespondingslotfromthemainwindow,you
caninquireandsetthestatusofacorrespondingMDBUmodule.