User's Manual Part 1

Confidential&Proprietary22/117 SCDAS
3.1 Systemspecifications
3.1.1
PhysicalSpecifications
Parameter BIU ODU OEU MRU ARU
RFConnectors
4SMApairs(TX,RX)
perMDBU
2SMA‐
1Ntype
2SMA:optical
2SMA:RF
2SMA:optical
2SMA:RF
External Alarm
connector
(Drycontacts)
TB:4pcsforoutput
TB:3pcsforinput
‐ ‐ ‐ ‐
Serial Interface
connector
1USB(B)type 1USB(B)type 1USB(B)type 1USB(B)type
Fiberconnector‐
8pcs, SC/APC for
ROU
1SC/APCforODU
8SC/APCforROU
1SC/APCforODU‐
LEDAlarmand
StatusIndicator
MDBUStatus
Powerstatus
ALMstatus
MCPU
Powerstatus
TXComm
RXComm
ALMstatus
MPSU
Powerstatus
DCALMstatus
DOU1Status
LDstatus
PD1/2/3/4
status
DOU2Status
LDstatus
PD1/2/3/4
status
EWDM
Status
LDstatus
PDstatus
DOU1Status
LDstatus
PD1/2/3/4
status
DOU2Status
LDstatus
PD1/2/3/4
status
Systemstatus
Powerstatus
TX1Comm
RX1Comm
TX2Comm
RX2Comm
ALMstatus
Systemstatus
Powerstatus
TX
Comm
RXComm
ALMstatus
Optstatus
Systemstatus
Powerstatus
TXComm
RXComm
ALMstatus
ACPower‐
Normal Range: 120VAC
50/60Hz
Operatingrange
108~132VAC,50/60Hz
Sametoleftside
DCPower
Normal range:‐48
VDC
Operatingrange:
40.8~‐57.6VDC
BeprovidedbyBIU
Normal:‐48VDC
Operatingrange:
40.8~‐57.6VDC
Sametoleftside
Power
consumption
SISOMode:162W
(Including SISO ODU
4EA)
MIMOMode:315W
(Including SISO ODU
4EA+MIMO ODU
4EA)
28W
(Including
DOU2EA)
40W
(IncludingDOU2EA)
MRU1900P+850C:50W
MRU1900P:45W
MRU700LTE+AWS:50W
MRU700P+800P:50W
ARU700LTE+AWS:40W
ARU900I+800I:44W
Enclosure
Dimensions
482.6(19”) x
221.5(5U)x450
482.6(19”) x
43.6(1U)x450
482.6(19”)
x88.1(2U)x450
300x200x258 300x200x258
Weight[FullLoad] 26.2Kg 6Kg 9.6Kg 6.6Kg~7.1Kg 6.8Kg