4.4.4 Function by unit
1) Remote Drive Unit (RDU)
When receiving TX signals from each band through Remote Optic, RDU filters the signals and
amplifies them with High Power Ampifier. The unit also filters RX signals given through
Multiplexer and amplifies them to send the signals to Remote Optic.
In the unit, there is ATT to adjust gain. RDU devices are varied for each frequency band,
including the following:
No Unit naming Description
BPF
TX RX
1 RDU 800PS Single, External BPF Internal BPF
2 RDU 850C Single, External BPF External BPF
3 RDU 1900P+AWS-1 Dual,
External BPF(1900P)
Internal BPF(AWS-1)
External BPF(1900P)
Internal BPF(AWS-1)
4 RDU 800PS+900I+PA Dual,
External BPF(800PS)
Internal BPF(900I+PA)
Internal BPF(800PS)
External BPF(900I+PA)
5 RDU 850C+700PS Dual,
External BPF(850C)
Internal BPF(700PS)
External BPF(850C)
Internal BPF(700PS)
6 RDU VHF+UHF Dual Internal BPF(VHF,UHF) Internal BPF(VHF,UHF)
7 RDU E-VHF+UHF Dual Internal BPF(VHF,UHF) Internal BPF(VHF,UHF)
8 RDU 850C+700LTEC Dual,
External BPF(850C)
Internal BPF(700LTEC)
External BPF(850C)
Internal BPF(LTEC)
9 RDU 700LTEF SISO Single, Internal BPF
External BPF(SISO)
Internal BPF(MIMO)
10 RDU 700LTEF MIMO Single, Internal BPF
External BPF(SISO)
Internal BPF(MIMO)
11 RDU 700LTEF+850C Dual,
External BPF(850C)
Internal BPF(700LTEF)
External BPF(850C)
Internal BPF(LTEF)