User's Manual

Confidential&Proprietary96/122 SCDAS
Checkingthestatusofthesystem’sLEDIndicator
AfterturningontheswitchofthepowersupplyinBIU,checkinformationoneachmodule’s
LEDofthesystem.Thetablebelowshowsnormal/abnormalcasesdependingonthestatus
ofeachmodule’sLED.
LEDinformation
Unit LED Indicates
ONGreen:MDBUisnormallypowersupplied.
Green:MDBUisnormal.
MDBU
ALM
Red:MDBUisabnormal;checkthealarmthroughRS232C.
ON
Green:MCPUisnormallypowersupplied.
TXD
Greenflicker:TXsignalsaretransmittedtocommunicatewithROU.
RXD
Greenflicker:RXsignalsarereceivedfromROU.
Green:BIUsystemisnormal.
MCPU
ALM
Red:BIUsystemisabnormal;checkthealarmthroughRS232C.
ONGreen:BIUisconnectedwithpowerandMPSUworksnormally.
Green:DCoutputisnormal.
MPSU
ALM
Red:DCoutputisabnormal.
MDBUSetting
Insert the MDBU into the BIU. Check if the “ON” LED Indicator at the front panel of MDBU is lit
green.MakeaconnectionwithDEBUGportoftheMCPUthroughUSBCable
CheckiftheIDofMDBUmoduleislocatedinthoseSISOMDBU#1&2,MIMOMDBU#1&2slotsofthe
MDBUthroughtheGUI.Whenyouselectthetabofacorrespondingslotfromthemainwindow,you
caninquireandsetthestatusofacorrespondingMDBUmodule.