User's Manual

Confidential&Proprietary58/122 SCDAS
This chapter describes how to install each unit and corresponding fiber cables, along with power
cablingmethod.
In detail, the chapter describes how to install shelves or enclosures of each unit, Power Cabling
method,OpticCablingand RFInterface.Furthermore,byshowingpowerconsumptionofmodules
installedineachunit,athePowerCablingbudgetiseasilydetermined.Last,itdescribesthequantity
ofcomponentsofmodulestobeinstalledineachunitalongwithanexpansionmethod.
5.1 BIUInstallation
5.1.1 BIUShelfInstallation
Generally, the BIU is installed in a 19” standard rack. This unit has handles on each side for easy
placement.Withtwomountingholesoneachside,youcanfirmlyfixtheunitintoa19”rack.
Figure5.1RACKInstallation
BIUhasthefollowingcomponents:
No. Unit Description Remark
Shelf IncludingMainBoard,19”,5U 1EA
MPSU Operate‐48VdcInput 1EA
MCPU WithEthernetPortandUSBPort 1EA
CommonPart
PowerCable‐48VdcInputwithtwolugterminal 1EA
MCDU‐ 1EA
SISOSlot
MDBU TwoamongMDBU Upto2EA
MCDU‐ 1EA
MIMOSlot
MDBU TwoamongMDBU Upto2EA
Basically, the frame of the BIU has slots equipped with an MPSU to supply devices with poweran