4.4.4 SubAssemblydescription
1)MainRFModule/AddonRFModule(MRFM/ARFM)+BPF
When receiving TX signals from each band through ROpt, MRFM/AFRM filters the signals and
amplifies them with the High Power Ampifier. The unit also filters RX signals received through the
antennaportandamplifiesthemaslownoisetosendthesignalstoROpt.
Intheunit,thereisanATTtoadjustgain.Thisdevicevariesforeachfrequencyband,includingthe
following:
BPF
No Combination Unitnaming Description
CavityFilter CeramicFilter
MRU1900P+850C MRFM1900P+850C Dual. 1900PCS 850C
1
ARU700LTE+AWS1 ARFM700LTE+AWS1 Dual. 700LTE AWS1
MRU1900P MRFM1900P Single 1900PCS‐
2
ARU900I+800I ARFM900I+800I Dual 900IEN/800IDEN‐
3 Tobedeveloped‐
2)RemotePowerSupplyUnit(RPSU)
RPSUaccepts‐48VDCinput.Thisunitisconfigured2ways:theDC/DCtypeoutputs+25VofDCpower
andAC/DCtypetakes120VACinputandoutputs+25VofDCpower.
Please specify which type when ordering. MS Connector, which uses ports to receive inputs, is
designedforeither AC andDCinput configuration. The input cableisdifferent depending on input
voltageconditions.
TheRPSUdoesn’thaveaswitchtoturnthepowerON/OFF.Unitisactivewhenpowerisconnected.
Here,youshouldcheckforrangeofinputpowerasfollows:
No. Unit Rangeofinputpower Remark
1 AC/DC 90to264VAC
2 DC/DC
42Vto‐56VDC

(a)AC/DC(b)DC/DC