User's Manual
Confidential&Proprietary119/122 SC‐DAS
ThischapterdescribesadditivefunctionsofSC‐DAS
7.1 Shutdownfunction(TXoutputshutdown)
The DAS has an automatic shutdown function to protect the DAS itself and the wireless
networkwhenthenormaloperationalconditionscannotbemaintained
Shutdownistriggeredautomaticallywhenthecompositepowerdownlinkoutputisabove
thevaluesdefined as averageforthe devicefora period nottoexceed
5seconds. Critical
levelsaresetthroughtheGUI
After automatic shutdown, the system may automatically turn‐on in order to assess
whether the temporary condition has changed. If the condition is still detected, the DAS
shallshutdownagain.Thisactionwillberepeated5times
AfterThe5
th
time,iftheconditionisstilldetected,theDASwillbeshutdownpermanently.
Thefollowingdiagramshowstheshutdownlogic
Figure7.1–Shutdownlogicdiagram
Aftertheretrylogicexhaustsitself,theDASwillshutdownpermanentlyandilluminatethe
faultviavisualfaultindicator
PermanentshutdownsoftheDASwillalsobereportedtotheNOCthroughtheNMS
7.2 TotalPowerLimitfunction(TXOutputALC)
InordertoprotecttheHPAandnottoradiatespuriousemissions,outputpowersislimited
to a defined value which is set by the operator in advance. To execute this function,
operatorshouldturn‐ontheALCfunctionandsetlimitlevelthroughtheGUI.Iftheoutput
power
exceeds the defined value, the output attenuator is adjusted to return it within
defined value. The output attenuator’s adjustment range is 25dB max. If output power
decreases, attenuation is decreased using the AGC function to return to the initial
attenuationlevel.