User's Manual
Confidential&Proprietary114/122 SC‐DAS
After turning on the switch of the power supply in the OEU, check information on each
module'sLEDofthesystem.Thetablebelowshowsnormal/abnormalcasesdependingon
thestatusofeachmodule'sLED.
Unit LED Indicates
Green:LaserDiodenormalstatus
LD
Red:LaserDiodeabnormalstatus
Green:PhotoDiodenormalstatus
EWDM
PD
Red:PhotoDiodeabnormalstatus,inputopticpowerlowalarm
Green:LaserDiodenormalstatus
LD
Red:LaserDiodeabnormalstatus
Green:PhotoDiode(PD)ofopticport1isnormal
PD1
Red:PDofopticport1isabnormalorinputopticpowerlow
Green:PhotoDiode(PD)ofopticport2isnormal
PD2
Red:PDofopticport2isabnormalorinputopticpowerlow
Green:PhotoDiode(PD)ofopticport3isnormal
PD3
Red:PDofopticport3isabnormalorinputopticpowerlow
Green:PhotoDiode(PD)ofopticport4isnormal
DOU1,2
PD4
Red:PDofopticport4isabnormalorinputopticpowerlow
ON
Green:Poweron
TXD1
Greenflicker:ECPUsendNMSTxdatatoBIU
RXD1
Greenflicker:ECPUreceiveNMSRxdatafromBIU
TXD2
Greenflicker:ECPUsendNMSTxdatatoROU
RXD2
Greenflicker:ECPUreceiveNMSRxdatafromROU
System
ALM
Green:OEUsystemnormal(noalarm)