User's Manual

Confidential&Proprietary106/122 SCDAS
6.2.1 ROUOperation
The ROU is a onebody enclosure type and is located at a remoteclosetinthebuilding.It
canbeinstalledonawallorintoarack.
Basically,onlyoneantennaportisprovided.Toinstallmultipleantennas,youneeddividers
and/orcouplers.TheROUcanworkwithaDCFeederandanOpticCableFeeder.Topower
the ROU, a power supply of either ACDC or DCDC can be selected depending on the
application.
Forupperlevel,theROUcanbeconnectedwiththeODUandOEU.IthasanAGCfunction
for5dBoofoptical
cableloss.
ThefollowingshowsoperationalproceduresafterinstallationoftheROU.
CheckingthestatusofROU'sLEDIndicator
When power cable is plugged into an outlet, power is provided for the ROU. Check
informationoneachmodule'sLEDofthesystem.Thetablebelowshowsnormal/abnormal
casesdependingonthestatusofeachmodule'sLED.
CheckingCommunicationLEDofROU
Check if TXD and RXDLEDsin the MRU make communication. ReceivingFSKsignalsfrom the BIU,
LED
Description
Powerisnotsupplied
ON
Powerissupplied.
NormalOperation
ALM
AbnormalOperation
ROPTisnormaloperation
OPT
ROPTisabnormalOperation
TXD
Flashingwhendatasendtoupperunit
RXD
Flashingwhendatareceivefromupperunit