User's Manual

Confidential&Proprietary105/122 SCDAS
The level of DOU’s Laser didoe is typically +1.5±1dBm. DOUs have various alarm such as LD Power
alarm,OverloadAlarmandPDalarms.
The level of Laser diode receivedfrom ROU/OEUis +7dBm±0.5dB.The level of Photo diode willbe
displayedwithlossesrelatedtothelengthofopticalcablesandinsertionlossofopticalconnectors.
Ingeneral,thelevelofopticalPDPOWERshouldbe+6dBmto+2dBm±1.5dB.
Furthermore,theODUhasthefunctionofautomaticallycompensatingforopticalcableloss.
Initially, if BIU communicates with the lower Unit(OEU,ROU), the optical loss compensation is
automaticallyaffected.
Duringopticalcompensation,theResultwindowshows"Processing"andthenaresultvalue.There
arethreetypesofresultsasfollows:
A. Success:Theopticalcompensationisnormallycompleted
B. OverOpticLoss:Generatedopticallossis5dBoormore.
C. CommunicationFail:CommunicationwithROUisinpoorconditin.
The ATT foroptical compensation can work based on the numerical expression of 122*(LD
POWERPDPOWER).OpticalcompensationcanbemadenotonlyintheODUbutalsointheROU.
6.2 ROUOverview
The figure below shows the SCDAS system link level (BIUODUROU). This section describes ROU
related information. The ROU receives various signals through optical modules. These signals are
filtered only for corresponding signal band from the MFR/ARF module and amplified with a High
Power Amplifier. Then, the multiplexer combines the signals with others and sends them to the
antennaport.

Figure6.11–SCDASLinkbudgetforROU