User's Manual
Confidential & Proprietary 26/30 SC-DAS
3.1.3 Optical Cabling
MRU makes optical-electronic conversion of TX signals from upper ODU and OEU and makes
electronic- optical conversion of RX signals. MRU has one optical module in it. As WDM is installed in
the R_OPT module, two pieces of wavelength (TX:1310nm, RX:1550nm) can be sent/received with
one optical strand at the same time. MRU has SC/APC of optical adaptor type.
For optical adaptor, SC/APC type can be used. To prevent the optical access part from being marred
with dirt, it should be covered with a cap during move. When devices are connected through optical
cables, you are recommended to clear them using alcohocol to remove dirt.
Figure 3.11 – ROU optical Port Look
Only MRU has optical port but ARU don’t have optical port
3.1.4 GND Terminal Connection
ROU has one GND terminal port where is on bottom side, like below