Installation Guide
Solid State Logic Digital Broadcast Console Installation Guide Version 1.2.
C100 Installation Guide Solid State Logic S O U N D || V I S I O N Begbroke, Oxford, England, OX5 1RU • +44 (0)1865 842300 320 West 46th Street, 2nd Floor, New York, NY 10036, USA • +1 (1) 212 315 1111 Suite 401, 5757 Wilshire Blvd, Los Angeles, CA 90036, USA • +1 (1) 323 549 9090 3-55-14 Sendagaya, Shibuya-Ku, Tokyo 151-0051, Japan • +81 (0)3 5474 1144 7 bis, rue de la Victoire, le Blanc Mesnil, Paris 93150, France • +33 (0)1 48 67 84 85 Via Timavo 34, 20124 Milano, Italy • +39 (0)39 2328 094 Visit SSL
Contents 1 Introduction 2 Safety Considerations Safety Warnings CE/FCC/WEEE Certification and Directives 2 3 4 5 3 Pre-Installation Information Services Provided by SSL Physical/Structural Console Footprint and Side Profile Centuri and Stagebox Side View Technical 6 6 7 8 10 11 5 Installation Connections Earth Connection Console Control PSU Status Sync I/O – MicAmp Card I/O – Analogue Card I/O – Digital Card I/O – MADI Card GPI/O Card C-SB Stagebox Wiring Talkback and Oscillator Phasescope and Meter W
C100 Installation Guide Section 1 – Introduction The object of this manual is to provide purchasers of the C100™ Console and Centuri™ Processor with information in the following areas: • Safety considerations • Installation requirements • Items supplied: – Main components and optional items • Installation: – Physical assembly – Electrical connections and cabling – System options • Specifications and Physical dimensions • Pinouts of standard connectors The information provided by this manual is releva
Section 2 Safety Considerations Section2 – Safety Considerations This section contains definitions and warnings, and practical information to ensure a safe working environment. Please take time to read this section before undertaking any installation work. Definitions ‘Maintenance’ All maintenance must be carried out by fully trained personnel. Note: it is advisable to observe suitable ESD precautions when maintenance to any part is undertaken.
C100 Installation Guide Safety Earth Connection Any mains powered item of SSL equipment that is supplied with a 3-core mains lead (whether connectorised or not) should always have the earth wire connected to the mains supply ground. This is the safety earth and grounds the exposed metal parts of the racks and cases and should not be removed for any reason.
Safety Considerations Section 2 CE Certification Note that the majority of cables supplied with SSL equipment are fitted with ferrite rings at each end. This is to comply with current European CE regulations and these ferrites should not be removed. If any of the console metalwork is modified in any way – particularly the addition of holes for custom switches etc. – this may the adversely affect the CE certification status of the product.
C100 Installation Guide Section 3 – Pre Installation Information Physical installation of the console is normally carried out by a specialised transportation company. In some cases this will have been arranged by the local SSL office, in other cases by the facility. The cables that run between console and processor can be shipped in advance of the console in a separate kit (the pre-install kit). These cables should be installed by the facility engineers.
Section 3 Pre Installation Information Physical Requirements Console Control Surface The console control surface can be specified to have from 8 to 96 channels so the size and weight will vary considerably. A dimensioned footprint drawing for each specific console control surface can be provided by SSL’s Project Engineering Department. See page 8 for an example of a 32-channel footprint. Consoles can be built with split points at any profile (at additional cost).
C100 Installation Guide 32 Channel Footprint 956 988 640 1776 283 1 8 9 53 16 17 24 Master 25 32 334 Console legs can be located at any position along console beam. Maximum distance between legs is 1,336mm (ie. four bays) 80 min.
Section 3 Pre Installation Information Air Conditioning Requirements Air conditioning will almost certainly be required for both the Machine and Control rooms in order to maintain the temperature and humidity to within the required levels. Power dissipation figures for console control surface and equipment rack are listed in Appendix A. Appendix E contains the environmental specification for SSL equipment.
C100 Installation Guide Centuri Processor Crate (side view) Showing Card Access 270 592 270 15U Rear Front C-SB Crate (side view) Showing Card Access 462 270 14U Rear Page 10 Dimensions in mm Front
Section 3 Pre Installation Information Technical Requirements Video Sync Source The Centuri Processor requires a feed of video sync. Other sources – MIDI or wordclock etc. – cannot be used as the sync reference. The sync required is 75Ω 1V(pk-pk) black-and-burst video. The standard can be either PAL (625 line, 50Hz) , NTSC (525 line, 59.94Hz or 60Hz). Composite sync may also be used.
C100 Installation Guide C100 Channel Bay Layout UBus 1 1 Chan: 17 DCart C 2 Chan: 18 POST PROC 0 INPUT 0 3 3 1 EVS 6 3 Chan: 19 PRE PROC 0 1 2 6 9 3 12 18 20 18 20 15 15 24 ∆t 1 2 3 4 5 9 6 10 7 11 8 12 21 22 23 24 13 14 17 15 18 A1 A3 A6 2 8 12 21 22 23 24 13 14 17 A5 15 18 A1 18 20 18 20 18 20 18 20 18 20 24 A3 A6 2 4 6 10 7 11 8 12 21 22 23 24 13 14 17 A8 A5 A1 PGM 2 3 5 9 20 A4 A7 PGM 1 1 15 18 A2 A6 PGM 1 ∆t 1 16
Section 4 System Components Section 4 – System Components This section gives an overview of the main units in the system. See Appendix A for specifications and Appendices B and C for connector details and pinouts. C100 Console Each console control surface will consist of one Centre Section and can be specified to have from 8 to 96 channel faders in groups of 8. (Note: a group of 8 faders and controls and its frame is termed a bay). See page 10 for frame sizes.
C100 Installation Guide I Centuri Processor Crate (Front View) I O O -15V +15V +5.5V +5V +3.3V -15V +15V +5.5V +5V +3.
System Components Section 4 The Centuri Processor The Centuri processor is a 15U high 600mm deep rack unit. Cards are fitted to the front and rear of the chassis so space for access is essential. See page 10 for chassis dimensions and minimum service clearance. At the front of the processor are located the plug-in PSU units. One unit is capable of powering the system. The panel below the power supplies is fitted with either a 250Mb Zip drive or an SD memory card reader.
C100 Installation Guide ETHERNET Solid State Logic OXFORD•ENGLAND DSP CARD +5V +3V3 FLAG 1 FLAG 12 DISK CARD VIDEO 1 MACHINE TIME CONTROL CODE ROUTING CARD +5V +3V3 SCSI A SCSI B VIDEO 2 RESET VIDEO 3 SYNC SCSI B CONTROL SURFACE 1 PORT 2 CONTROL SURFACE 2 SERIAL PORT 1 CONTROL SURFACE 3 2 1 DSP Card Page 16 System Disk Card CPU Card Console Interface Card Routing/Link Card
System Components Section 4 Centuri – DSP Card The DSP cards supply the signal processing function for the Centuri system. Each card provides 32 channels of processing. DSP cards are all the same and do not require configuration, they can therefore be fitted into any of the first 5 slots in the front of the Centuri rack. For a system to pass any audio, there must a card fitted in slot 5 and a card in slot 1. Centuri – Disk Card This is a 1.
C100 Installation Guide AES/EBU IN +5V SPLIT OUTPUTS 7-12 ANALOGUE IN 1 - 24 MADI IN GPI OUT LOCK Rx A A1 9 - 16 1-8 Tx 49 - 60 49 - 60 37 - 48 37 - 48 25 - 36 25 - 36 13 - 24 13 - 24 1 - 12 1 - 12 LOCK Rx 1-6 25 - 32 17 - 24 B Tx IN AES/EBU OUT MIC IN 1 - 12 ANALOGUE OUT 1 - 24 WORD SYNC OUT A1 9 - 16 1-8 IN AES SYNC OUT 25 - 32 Mic Input Card 12 Microphone inputs 12 split outputs Page 18 Analogue I/O Card 24 line level inputs and outputs 17 - 24 Digital I/O Card
Section 4 System Components Centuri – Micamp Card The Microphone input card (generally known as the BMA or ‘Broadcast Mic Amp’) provides 12 input channels. The input is via a female Varicon (EDAC) connector. Mating connectors can be supplied as a cost option. Each of the mic inputs has a buffered split output. The buffering takes place after the input pad, the RFI filter and the 25KHz low-pass filter but before the variable gain stage.
C100 Installation Guide SELECT Solid State Logic OXFORD•ENGLAND (NO) (YES) SELECT TALKBACK MONITOR LEVEL PUSH +48V OVER LOAD OVER LOAD SIG SELECT CH3 CH4 SELECT PUSH SELECT PUSH PUSH SELECT SELECT PUSH +48V SIG OVER LOAD PUSH SELECT SELECT SIG OVER LOAD PUSH SELECT +48V +48V +48V +48V OVER LOAD OVER LOAD OVER LOAD OVER LOAD SIG SELECT SIG PUSH SELECT SIG PUSH SELECT PUSH SELECT +48V OVER LOAD OVER LOAD OVER LOAD OVER LOAD OVER LOAD SELECT PUSH SELECT PU
Section 4 System Components C-SB Stagebox (option) The C-SB is a Mic/Line input/output stagebox which can be located remotely from the Centuri chassis. It operates at 48KHz sample frequency and is a 14U high, 462mm deep, rack-mounted unit. At the front of the unit are nine slots for plug-in cards: six slots for mic/line input cards; two slots for line output cards and one for the CPU card. At the rear is an auto-ranging switch-mode power supply.
C100 Installation Guide NetBridge (Front View) Solid State Logic NetBridge NetBridge (Rear View) SERIAL 1 - 8 SSL SERIAL 9 TERMINAL TCP/IP TESTED DATE 230 Model Serial No. 626755X4 Ratings: AC ~ 50/60Hz Volts Amps 90-125 1.2-0.9 195-255 0.6-0.
Section 4 System Components NetBridge (option) NetBridge is a 2U rack mounting unit. The NetBridge provides two main features. Firstly (as the name suggests) it is a bridge between the proprietary Solid State Logic network, and the standard TCP/IP protocol, allowing remote diagnostic connection over the Internet.
C100 Installation Guide Location Of Bellypanel USB Connectors CTRL 2 CTRL 1 ETHER 4 Page 24 ETHER 3 ETHER 2 ETHER 1 T/SCR BT/PAD KBD CTRL 3 USB MIC GN
Section 4 System Components External Keyboard / Trackball (options) There is an inbuilt software keyboard included in the C100 system. This is accessed via the Centre Section touch screen. Alternatively an external USB computer keyboard and or USB mouse/trackball may be connected to the audio connector panel using the connectors provided. The diagram opposite shows the location of these connectors. Script Tray (option) The script tray is a movable transparent panel which fits over a channel bay.
C100 Installation Guide Console Mains Inlet Panel POWER IN BACKUP POWER IN Earth Bolt Centuri Mains Inlet Panel PSU 1 PSU 1 O O I I CONSOLE POWER INDICATORS REMOTE POWER INDICATORS Earth Bolt NetBridge Rear Panel SERIAL 1 - 8 SSL TCP/IP SERIAL 9 TERMINAL TESTED DATE 230 Model Serial No. 626755X4 Ratings: AC ~ 50/60Hz Volts Amps 90-125 1.2-0.9 195-255 0.6-0.
Installation Wiring Section 5 Section 5 – Installation Wiring This section provides the details for connecting the system components together. Power Supply Connections This section refers to the following supplied cables (: Description Con IEC Free Socket 6A 2m Cable Power Digital 2m Lead Chassis Earth 16m SSL Part No.
C100 Installation Guide Control Surface Wiring - Block Diagram Control Card CPU Card ETHERNET MACHINE TIME CONTROL CODE VIDEO 1 VIDEO 2 VIDEO 3 RJ45 Ethernet lead SYNC XGA video lead CONTROL SURFACE 1 CONTROL SURFACE 2 SERIAL CONTROL SURFACE 3 TTY-B 906XA TTY-G 960XA TTY-C RS422 serial cables x 3 CTRL 1 ETHER 4 VIDEO IN MSD DIAG ETHER 2 ETHER 1 T/SCR CTRL 1 BT/PAD KBD ME INP Audio Connector Panel Page 28 ETHER 3 Front Panel cables x 2 Console Connector Panel CTRL 1 USB
Installation Wiring Section 5 Centuri to Console Surface Connections This section refers to the following supplied items: Description Lead 9WD plug to 9WD plug 16m Lead RJ45 Shielded 15m Lead Video HD15W D-Type 16m Loom 36-way H/D Digital 16m Cable assembly 62 way plg to 8 x 9WD plg 1m Adapter 9 way D con F to F SSL Part No.
C100 Installation Guide PSU Status Wiring Diagram PSU 1 PSU 1 O O I I CONSOLE POWER INDICATORS VIDEO IN MSD DIAG METER INPUTS PHASE SCOPE REMOTE POWER IN D1 REMOTE POWER INDICATORS D2 CPU Card D3 D4 Sync Input connector SYNC Page 30 D5 EXT T/B MIC IN TALKBACK OUTPUT X1 X2 Console Audio Connector Panel
Installation Wiring Section 5 PSU Status This section refers to the following supplied items: Description Cable 25-way D Plug to Socket 16m screened SSL Part No. 66C67781 qty 1 Note a) The PSU Status cable carries the status indication of the two Centuri crate PSU units. Install the the 25 pin male to female lead and connect as shown opposite; the male end of the cable connects to the Centuri and the female to the console. Note that the 9-way connector ‘Remote Power Indicators’ is not used.
C100 Installation Guide Analogue I/O Card Micamp Input Card +5V SPLIT OUTPUTS ANALOGUE IN 1 - 24 7-12 A1 Analogue Input Connector DL96 female Split Output Connectors 25-pin D-type female 1-6 ANALOGUE OUT 1 - 24 MIC IN 1 - 12 A1 Microphone input Connector Varicon 56-way female Page 32 Analogue Output Connector DL96 female
Section 5 Installation Wiring I/O – MicAmp Card (SSL ref. 908) Each MicAmp Input Card contains 12 Microphone circuits. The inputs are accessed via a Varicon (aka. EDAC or Elco) 56-way female connector. The split outputs are accessed via two 25-pin D-type female connectors. Refer to Appendix C for the connector pinouts. SSL is able to supply mating connectors if requested, (at additional cost).
C100 Installation Guide Digital I/O Card MADI I/O Card (Copper version) (D25 version) AES/EBU IN MADI LOCK Rx 9 - 16 1-8 AES/EBU Input Connectors 25-pin D-type female A Tx MADI Link A BNC 75Ω LOCK Rx 25 - 32 B 17 - 24 Tx IN AES/EBU OUT WORD SYNC MADI Link B BNC 75Ω MADI Word Sync BNC 75Ω OUT 9 - 16 1-8 AES/EBU Output Connectors 25-pin D-type female IN AES SYNC OUT 25 - 32 17 - 24 Page 34 AES Sync BNC 75Ω
Section 5 Installation Wiring I/O – Digital Input/Output Card 110Ω (SSL ref. 902XF) The Digital Input Card provides 32 balanced AES/EBU signal pairs of both input and output. All circuits are accessed via 25-pin D-type female connectors. Refer to Appendix C for the connector pinout for this card. Mating connector kits can be ordered for the card. As in the case of the Analogue I/O, cards added subsequently should be placed to the left of existing cards. Note.
C100 Installation Guide GPI I/O Card IN GPI OUT GPI input Connectors 25-way D-type Male Page 36 GPI output Connectors 25-way D-type Female 49 - 60 49 - 60 37 - 48 37 - 48 25 - 36 25 - 36 13 - 24 13 - 24 1 - 12 1 - 12
Installation Wiring Section 5 I/O – GPI I/O (SSL ref. 907XA) The GPI I/O Card contains 60 circuits of opto-isolated input and 60 circuits of relay-closure output. Inputs are accessed by 25-pin D-type male connectors and outputs by 25-pin D-type female connectors; mating connector kits are available to order. Both the input and the output circuits are fully isolated from the processor electronics.
C100 Installation Guide 4 PORT 2 3 2 Fibre Link Connectors and Panels Centuri Link Card With four redundant links CH1 CH2 CH3 CH4 1 1 4 FIBRE LINK 2 PORT 1 3 C-SB CPU Card With redundant Fibre Link 2 1 NETWORK C-SB Cabling Diagrams Centuri Processor Network Fibre i/f 1a C-SB audio link LC control link Ethernet hub/switch LC Fibre i/f 1a Single Fibre-Link with RJ45 control link (100m max) Network duplex fibre link RJ45 ethernet Centuri Processor Network Fibre i/f 1b Fibre i/f
Section 5 Installation Wiring Stageboxes & Fibre Links The C-SB Stagebox utilises fibre-optic connection between itself and the Centuri Processor. This has the advantages of noise immunity, reduced weight and bulk of wiring and the elimination of earth loops. A separate control signal (for gain, pad, filter etc.) is carried over the SSL ethernet network. This control signal can be converted into fibre optic for runs longer than 100m.
C100 Installation Guide NetBridge Installation Centuri CPU Card C100 Console ETHERNET V ID E O 1 V ID E O 2 V ID E O 3 SYNC ‘TTY-E’ 960XA S E R IA L SERIAL 1 - 8 SSL TCP/IP SERIAL 9 TERMINAL TESTED 230 DATE Model Serial No. Volts Am ps 90-125 1.2-0.9 NetBridge Maintenance Access Operational Access IN IT IA L S Solid State Logic Oxford • England 626755X4 Ratings: AC ~ 50/60Hz 195-255 0.6-0.
Section 5 Installation Wiring NetBridge Installation NetBridge has eight serial ports plus two Ethernet ports. The first Ethernet port is connected to the C100’s network. The second port is for connection to the Internet; this can be via DHCP server (for a dynamically assigned IP address), or a static IP address defined by the operator. The IP number (in ‘dot’ notation) will be shown on the front panel while the unit is powered.
C100 Installation Guide Talkback system - Block Diagram Centuri Chassis C100 Console Internal T/B Mic Talkback Output Analogue I/O card External T/B Mic in Mic gain trim controls Connector panels USB MIC GN D5 External mic gain trim Page 42 Internal mic gain trim PUSH CTRL 3 EXT T/B MIC IN TALKBACK OUTPUT X1 X2 External Mic Input and Talkback Mix Output
Section 5 Installation Wiring Talkback and Oscillator Talkback Connections The C100 console contains a built-in talkback microphone and amplifier. In addition, a second input is available for connection to an external dynamic microphone. This input is mixed with the internal T/B mic and the combined signal is available via an XLR connector on the audio interface panel beneath the console. This signal should be connected to an analogue input circuit in the Centuri processor.
C100 Installation Guide Meter and Phasescope wiring - MSD 600C PPM & Phasescope Panel +1 +12 +9 C EN TER +6 TEST –6 L LEFT R Centuri Crate –12 –18 –24 –30 RS LS –36 –42 –1 RIGHT Meters and Phasescope inputs VIDEO IN MSD DIAG METER INPUTS PHASE SCOPE REMOTE POWER IN Analogue I/O card Digital I/O card (Audio connector panel) 3 off AES/EBU ccts. 2 off analogue ccts.
Section 5 Installation Wiring Meters and Phasescope The Centre Section of the C100 console may optionally be fitted with an LCD phasescope and/or twin movingcoil mechanical meters (PPM or VU). Two standard phasescope types are available, the MSD600C or the RTW 10830. Other custom meter solutions may be possible. Cable connections to the meters and phasescope will need to be run between the Centuri and the Console.
C100 Installation Guide Gold is 1.9 times heavier than Lead.
Appendix A – Specifications Appendix A: Specifications C100 Console Parameter Height Height adjustment Width: (1) Depth Weight: Heat Dissipation Voltage Current Power Factor Fusing Noise Connectors: (1) Condition To top of meter trim Centre Section + End trims 8 fader channel bay 24ch Frame 8 Channel Bay (add/subtract) Additional Leg 24ch Frame 8 Channel Bay (add/subtract) Input Range @ Voltage Range, 24ch @ Voltage Range, 48ch None Fanless Mains/Backup power in Control Surface Ethernet 1–4 Video I
C100 Installation Guide Centuri Processor Crate Parameter Height: Width Depth Weight (1) Heat Dissipation Voltage Current Power Factor Fusing Noise Connectors: (1) Condition Case w/o rack ears 32 DSP, no I/O 64 DSP, 24 mics, 48AIO 128DSP, 48 Mics, 96 AIO Range Total @ Voltage Range 1.
Appendix A – Specifications Net Bridge Parameter Height: Width: Depth Weight (1) Heat Dissipation Voltage Current: Fusing: Noise Connectors: (1) Condition Case w/o rack ears Switch selectable @ 230 V @ 115 V 100/120 V Range 220/240 V Range Power In Network - TCP/IP Network - SSL Serial 1 - 8 Value Unit 2 U mm 89 19 in 432 mm 360 mm 10 Kg 45 W 115 or 230 V 0.2 A 0.5 A 3.15(T) A 3.
C100 Installation Guide C-SB Micamp Rack Parameter Height: Width: Depth Weight Heat Dissipation Voltage Current: Fusing: Noise Connectors: (1) Condition Case w/o rack ears Rack with 1 PSU unit Each micamp/output card Additional PSU (1) Range Total @ Voltage Range 1.25" Fanless Mains in Mains out (x2) Mic in Insert send out Audio I/O Network Value 14 620 19 432 300 19 1.7 5.8 380 90 - 255 10.0 - 3.9 6.3(T) Unit U mm in mm mm Kg Kg Kg W V A A Notes No I/O cards Max AC only Worst case with max.
Appendix B: Connector Details Appendix B – Connector Details DL 96-Pin Hood Plug 1 2 3 4 Socket 5 6 7 8 A B C D 70 E H J P Dimensions: Hood Free Socket K V 79 d n y D P Z f j t J U c m x C N Y s H T w B M X r CC BB AA F S b l v A 4 3 2 1 K L M N P L W 29mm x 69mm Free Plug A E E R R a a k k u u e h p z JJ HH FF EE DD NN MM LL KK 69 8 7 6 5 E H J N 4 3 2 1 Connectors Viewed From Wiring Side 68 Varicon™ 56-pin 7 8 8 7 6 5 C D F G L M 5 6 B F
C100 Installation Guide XLR 3-Pin Dimensions: Cable Dia: 19 x 60mm (approx.) 8-12mm (typical) Pin 1 Pin 2 Pin 3 Screen/Ground Hot (+ve) Cold (-ve) Dimensions: Cable Dia: 2 3 3 Socket Plug 15mm dia.
Appendix C: Connector Pinouts – C100 Console Appendix C – Connector Pinouts 'Meter Inputs' (Analogue) Location: Connector Type: Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 'Audio' interface Panel 25-way D-type male Description Meter 1 Input Meter 1 Input n/c Meter 2 Input Meter 2 Input n/c Meter 3 Input Meter 3 Input n/c Meter 4 Input Meter 4 Input n/c Meter 5 Input Meter 5 Input n/c Meter 6 Input Meter 6 Input n/c Meter 7 Input Meter 7 Input n/c Meter 8 Input Meter
C100 Installation Guide 'Phase Scope' (Digital) Location: Connector Type: Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 'Audio' Console Belly Panel 25-way D-type female Description Circuit 1 Circuit 1 Gnd Circuit 2 Circuit 2 Gnd Circuit 3 Circuit 3 Gnd Circuit 4 Circuit 4 Gnd Circuit 5 Circuit 5 Gnd Circuit 6 Circuit 6 Gnd Circuit 7 Circuit 7 Gnd Circuit 8 Circuit 8 Gnd n/c Notes – MSD600C Notes – RTW10830 + - AES/EBU In 1/2 AES/EBU Out 7/8 + - AES/EBU In 3/4 AES/EB
Appendix C – Connector Pinouts Connector Pinouts – Centuri Processor 'Video 1, 2 and 3' Location: Centuri - CPU Card Connector Type: HD15 D-type Female Description Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Notes Red Signal Green Signal Blue Signal ID Bit Unused Red Screen Green Screen Blue Screen n/c Ground ID Bit ID Bit Horizontal Sync Vertical Sync Unused 'Machine Control' Location: Connector Type: Centuri – Interface Card 25-pin D-type Male Not implemented on C100 'Timecode' Location: Connect
C100 Installation Guide 'Serial' Location: Centuri – CPU Connector Type: D9 pin no.
Appendix C – Connector Pinouts Mic Input Card (‘908) Mic IN 1 - 12 +5V SPLIT OUTPUTS 7-12 1-6 Location: 908 Micamp Connector Type: Varicon 56 way female cct. hot cold screen 1 2 3 4 5 6 7 8 9 10 11 12 D C A B V U R S n m k l K J E F Z Y W X t s p r P N L M d c a b y x u v Notes All other pins n/c Split Outputs 1 - 6 MIC IN 1 - 12 Location: 908 Micamp Connector Type: 25-way D-type female cct.
C100 Installation Guide Analogue I/O Card (‘904) Analogue IN / Analogue OUT ANALOGUE IN 1 - 24 A1 ANALOGUE OUT 1 - 24 A1 Page 58 Location: Connector Type: cct.
Appendix C – Connector Pinouts Digital I/O Card (‘902) AES/EBU In 1–8 (9–16, 17–24, 25–32) Location: AES/EBU IN 9 - 16 1-8 25 - 32 17 - 24 Connector Type: Cct 1 2 3 4 5 6 7 8 1-8 25 - 32 17 - 24 25-way D-type female Hot 24 10 21 7 18 4 15 1 Cold 12 23 9 20 6 17 3 14 Screen 25 11 22 8 19 5 16 2 Notes Pin 13 unused AES/EBU Out 1–8 (9–16, 17–24, 25–32) Location: AES/EBU OUT 9 - 16 902 DIO 902 DIO Connector Type: Cct 1 2 3 4 5 6 7 8 25-way D-type female Hot 24 10 21 7 18 4 15 1 Cold 1
C100 Installation Guide GPI I/O Card (‘907) GPI Inputs 1 - 12 (13 - 24, 25 - 36, 37 - 48, 49 - 60) Location: Connector Type: Pin 1 2 IN GPI OUT 3 4 5 49 - 60 49 - 60 6 7 8 37 - 48 37 - 48 9 10 11 25 - 36 13 - 24 25 - 36 13 - 24 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1 - 12 Location: Description Input Input Input Input Input Input Input Input Input Input Input Input Input Input Input Input Input Input Input Input Input Input Input Input 0V Connector Type: 1 2 3 4 5 6 7 8 9 10 11 12
Appendix C – Connector Pinouts Connector Pinouts – NetBridge Serial 1–8 (RS232) Location: Connector type: pin 1 2 3 4 5 6 7 8 9 Connector type: 2 3 4 5 6 7 8 9 Notes Chassis n/c Rx Data n/c Tx Data n/c n/c n/c Signal ground Location: 1 9-pin D-type male Description Terminal pin Netbridge rear panel Netbridge rear panel 9-pin D-type male Description DCD DSR Rx Data RTS Tx Data CTS DTR RI Signal ground Notes Data Carrier Detect Data Set Ready Request to Send Clear to Send Data Terminal Read
C100 Installation Guide Resistor Colour Code: Black 0 Brown 1 Red 2 Orange 3 Yellow 4 Green 5 Blue 6 Violet 7 Grey 8 White 9 Page 62
Appendix D – Audio Interfacing Appendix D: Audio Interfacing All analogue audio inputs and outputs are electronically balanced. The screen pins are all directly connected to the chassis at the point of entry to comply with AES/EBU grounding and EMC recommendations. Balanced Circuits It is strongly recommended that balanced connections are used wherever possible using high quality screened cable.
C100 Installation Guide 1 inch = 25.4mm (exactly) 1m = 3’ 3” (roughly) 1 mile = 1,600m (roughly) 1Kg = 2.
Appendix E – Environmental Specifications Appendix E: Environmental Specification Temperature Relative Humidity Vibration Shock Altitude (above sea level) Operating: Non-operating: Max. Gradient: 5 to 30 Deg. C -20 to 50 Deg. C 15 Deg. C/Hour Operating: Non-operating, power off: < 0.2 G (3 - 100Hz.) < 0.4 G (3 - 100Hz.) Operating: Non-operating: Max. wet bulb: Operating: Non-operating: Operating: Non-operating: 20 to 80 % 5 to 90 % 29 Deg. C (non-condensing) < 2 G (10mSec. Max.) < 10 G (10mSec.
C100 Installation Guide +4dBu = 1.229V rms. 0dBu = 0.775V rms. -6dBu = 0.388V rms.
Appendix F – Stagebox Installation Appendix F: Additional Information for Installing Stageboxes When positioning and installing C-SB the following rules must be followed: • Unobstructed airflow at front and rear. • No obstruction to airflow, horizontal or vertical, within 300mm in front, above and below both the front and rear panels. • Ambient temperature no more than 30˚C measured at the air intake (lower front opening) or just below the rear heatsink.
C100 Installation Guide This page is blank intentionally.
Appendix G – Part Numbers Appendix G: Cables and accessories Cables and Accessories - by Part Description Description Audio Cables and Accessories DL DL DL DL DL DL DL Connector Connector Connector Connector Connector Connector Connector Lead Lead Lead Lead Lead Lead Lead Lead DL DL DL DL DL DL DL DL - DL DL DL DL DL DL DL DL SSL Part No. Crimp Contacts .
Appendix E – Environmental Specification C100 Installation Guide Description SSL Part No.
Appendix G – Part Numbers Notes Page 71
C100 Installation Guide More Notes Page 72