User's Manual

X-Desk User Guide
Page 8
Control Room Monitoring
The DIM switch and dedicated DIM Level control allow the operator to immediately
reduce the monitoring volume. The DIM” level can range from a reduction of -3 dB
through to 30 dB. The DIM switch will illuminate when engaged.
The CUT switch mutes the monitoring path and will illuminate when engaged.
The MONITOR LEVEL control sets the control room monitoring listening level.
Monitor Sources
iJack The 3.5mm front panel socket
EXT A Stereo Line Input on the Centre In D-sub connector on the rear of the desk.
MIX The X-Desk MIX Bus
ALT L/S Allows you to listen to an alternate loudspeaker monitor set. Engaging this will
disable the primary Loudspeaker monitor Output. (MAIN L/S)
MONO - This will send the summed Left and Right Stereo signal to both monitor speakers.
Note: Remember if you do not select a monitor source you will not hear anything!
Power Up Options
There are two user selectable options available on powering up of the X-Desk.
Holding down the following buttons whilst switching on power will put the X-Desk in the
following operating states:
T/B (Talkback) Toggles the Talkback between Latching or Momentary
iJack, EXT and MIX Switches together alters the meter scaling between:
0 dbfs= 18 dBu
or
0 dbfs= 24 dBu
Note: that the default factory setting is 24 dBu