User Manual

Table Of Contents
Page 56 Duende Native User Guide
DETAIL PARAMETER RANGES AND DESCRIPTIONS
ER Menu
Menu Parameter Range Description
ER Master Controls
Master Delay 0 - 1500ms
Adds a Pre-Delay to the whole ‘ER Block’ so all individual
Taps move to the right.
Master Level 0 - 400%
Adjusts the level of all Taps, counter-clockwise to decrease,
clockwise to increase all tap levels.
M
aster Time
0
- 400%
A
djusts the delay of all Taps, counter-clockwise to decrease,
clockwise to increase all delay times.
Sub menus
for each Tap
Main
Delay 0 - 2500ms Tap Delay
Level –∞ to 0dB Tap Level
Phase On or Off Inverts phase of tap
Pan
–100 (L) to
+100 (R)
Places tap in stereo spectrum
Modulate
Cho Rate 0 - 4Hz
Adds a Chorus to the Tap to thicken and blur the reflection. At
0.00Hz the Chorus is switched off.
Cho Depth 0 - 100%
Adjusts the modulation depth of the Chorus. At 0% the
Chorus is switched off.
Filters
ER Rebound 0 - 100%
Adds a modulated Feedback Loop to the delay line of a Tap to
create complexity inside the Reflection.
Cutoff Freq 25Hz - 24kHz
Adjusts the Cut off Frequency of a smooth Low Pass Filter to
dampen the reflection and the rebounds.